Emerson 627F Manual de Instruções

Consulte online ou descarregue Manual de Instruções para não Emerson 627F. Emerson 627F Instruction Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 12
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
Type 627F
D101545X012
Instruction Manual
Form 5282
April 2012
www.sherregulators.com
Type 627F Pilot-Operated
Pressure Reducing Regulator
!
WARNING
Failure to follow these instructions or
to properly install and maintain this
equipment could result in an explosion
and/or re causing property damage and
personal injury or death.
Fisher
®
regulators must be installed,
operated, and maintained in
accordance with federal, state, and
local codes, rules and regulations,
and Emerson Process Management
Regulator Technologies, Inc. (Regulator
Technologies) instructions.
If the regulator vents gas or a leak
develops in the system, service to the
unit may be required. Failure to
correct trouble could result in a
hazardous condition.
Call a gas service person to service
the unit. Only a qualied person must
install or service the regulator.
Introduction
Scope of the Manual
This manual provides instructions for installation,
adjustment, maintenance, and parts ordering
information for the Type 627F regulator.
Figure 1. Type 627F Pilot-Operated Pressure Reducing Regulators
W5607
W5641
Vista de página 0
1 2 3 4 5 6 ... 11 12

Resumo do Conteúdo

Página 1 - Pressure Reducing Regulator

Type 627FD101545X012Instruction ManualForm 5282April 2012www.sherregulators.comType 627F Pilot-Operated Pressure Reducing Regulator!WARNINGFailure to

Página 2

Type 627F10Type 6351F Pilot (Figure 4)Key Description Part Number Parts Kit (included are keys 4, 6, 7, and 23) R6351X00012 1 Body Assembly,

Página 3

Type 627F11Figure 3. Type 627F Main Regulator Assembly32B3310_E635311048765829131211161714151855529313262613436565437232419L1L1L2L2L2L2L2APPLY LUBRIC

Página 4

Type 627F©Emerson Process Management Regulator Technologies, Inc., 2002, 2012; All Rights ReservedThe Emerson logo is a trademark and service mark of

Página 5

Type 627F21. The pressure/temperature limits in this Instruction Manual or any applicable standard limitation should not be exceeded.SpecicationsThe

Página 6

Type 627F3DescriptionThe Type 627F pilot-operated (Type 6351F pilot) pressure reducing regulator (Figure 1) provides economical, accurate pressure con

Página 7

Type 627F4When downstream pressure increases due to lowered demand, greater pressure is registered on the pilot diaphragm and the lever side of the ma

Página 8

Type 627F5To remotely vent the pilot, remove the vent and install obstruction-free tubing or piping into the 1/4 NPT vent tapping. Provide protection

Página 9

Type 627F6NoteAlways use a pressure gauge to monitor pressure when making adjustments.Shutdown!WARNINGTo avoid personal injury, property damage due to

Página 10 - Type 627F

Type 627F7These procedures are for gaining access to the disk assembly, orice, diaphragm casing, O-ring, and stem assembly. All pressure must be rel

Página 11

Type 627F8seat bolt (key 61) into tension spring (key 32) until the spring is ush with the top of the bolt threads as shown in Figure 3. Rotate the

Página 12

Type 627F9Diaphragm Parts1. Remove the closing cap (key 28), loosen the locknut (key 11), and back out the adjusting screw (key 10) to remove control

Comentários a estes Manuais

Sem comentários