Emerson MicroCEM Especificações

Consulte online ou descarregue Especificações para Acessórios para câmaras fotográficas/vídeo Emerson MicroCEM. Emerson MicroCEM Specifications Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 119
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
R
R
o
o
s
s
e
e
m
m
o
o
u
u
n
n
t
t
A
A
n
n
a
a
l
l
y
y
t
t
i
i
c
c
a
a
l
l
M
M
i
i
c
c
r
r
o
o
C
C
E
E
M
M
T
T
S
S
A
A
n
n
a
a
l
l
y
y
s
s
i
i
s
s
E
E
n
n
c
c
l
l
o
o
s
s
u
u
r
r
e
e
Micro Continuous Emission Monitor
Operation & Maintenance Manual
Revision 2.1, Oct. 13, 03
Part Number 1021021-100
Rosemount Analytical UCEM Continuous Analyzer Transmitter
Vista de página 0
1 2 3 4 5 6 ... 118 119

Resumo do Conteúdo

Página 1

RRoosseemmoouunntt AAnnaallyyttiiccaall MMiiccrrooCCEEMM TTSS AAnnaallyyssiiss EEnncclloossuurree Micro Continuous Emission Monitor

Página 2 - Preface

PREFACE Instrument Weight: 62 lbs Typical Size: 24“ X 20“ X 12“ (H W D) Ranges: O2: 0 –2 Selectable to 0 –25% (1% increments) CO: 0 –100ppm Se

Página 3

MAINTENANCE and SERVICE can be disabled at slow sample rates, so there is no lag time between sampling and data availability. The 16-bit interface fur

Página 4

MAINTENANCE and SERVICE trigger/control lines Counter/TimersA/D Pacer clock32-bit down counter (2 82C54 counters cascaded) Clock source10MHz on-board

Página 5 - PREFACE

MAINTENANCE and SERVICE 5.6.3.1 Features Dimensions: compliant with the PC/104 standard - Compatible with AT PC/104 CPU modules Functions on board:

Página 6 - POSSIBLE EXPLOSION HAZARD

MAINTENANCE and SERVICE Figure 5-11. Modem 5.6.4.1 Features V.90, 56 kbps data (560PC/104) V.34, 33.6 kbps data (336PC/104) 14.4 kbps fax Voice

Página 7 - CARRY THE INSTRUMENT

MAINTENANCE and SERVICE 5.6.5 Flash Drive Figure 5-12. 256MB Flash Drive. 5.6.5.1 Specifications Start-up time System Performance *Notes 1 & 2

Página 8 - PECIFICATIONS - GENERAL

MAINTENANCE and SERVICE Write 35 mA RMS 50 mA RMS Environmental Specifications Temperature: Operating Commerical 0°C to 60°C Operating Indus

Página 9

MAINTENANCE and SERVICE Physical Specifications Length 100.2mm ± 0.51mm Width 69.85mm ± 0.51mm Thickness (Body) 9.6mm ± 5.0mm Thickness (Remo

Página 10

MAINTENANCE and SERVICE 5.6.6 Pocket PC The Pocket PC acts as an Graphic User Interface to the µCEM unit. Figure 5-13 depicts the Pocket PC. Figure

Página 11

MAINTENANCE and SERVICE Features Serial cable Earphones Removable metal cover Password protected and DMI compatible Physical 5.2 × 3.

Página 12 - COMPLIANCES

MAINTENANCE and SERVICE ETSI - FCC part 15B, CE, ETS 300 328, ETS 300 826, C-Tick (Australia) Physical Specification: PC Card: PCMCIA Type II PC Card

Página 13 - 1. Introduction

PREFACE SPECIFICATIONS – Probe/Sample Handling Enclosure: GENERAL Power: Universal Power Supply 85 – 125 VAC, 50 – 60 Hz, + 10% 750 Watts M

Página 14 - INTRODUCTION

MAINTENANCE and SERVICE • Fan Output Voltage and Optional Fan • Optional Isolation Diodes for Parallel or Redundant Operation 5.7 Replacement Parts WA

Página 15 - 1.2 Time Shared Option

MAINTENANCE and SERVICE PARTS LIST Item Vendor Mfg. Part Number Description 1 CSTS 1020968-100 Assy, Power Supply 2 CSTS

Página 16

MAINTENANCE and SERVICE 42 CSTS 1020908-100 Cable Assy, Gas Valve Control 43 44 CSTS 1021115-100 Cable Assy, SHU#1 I/O 45 CSTS 31503 CH

Página 17 - 1.3 Theory of Operation

MAINTENANCE and SERVICE 89 Westam Rubber 31412 1/4 inch tubing, Viton 90 RMT-GMBH 337489 Desicannt Bulbs 91 Sante Fe Rub. Prod. 632784 1/4glass x

Página 18 - 1.3.3 O2

MAINTENANCE and SERVICE 134 CSTS 1020976-101 ASSY, CPU, PC104 135 CSTS 1020977-100 ASSY, I/0, PC104 136 CSTS 1021119-100 Cable Assy, EXT I/O Int

Página 19 - 1.3.4 SO2

MAINTENANCE and SERVICE 181 CSTS 31391-9 Insulation, Enclosure 182 CSTS 31391-10 Insulation, Enclosure 183 CSTS 31391-11 Insulation, Enclosure 1

Página 20 - 2. Detector Methodologies

MAINTENANCE and SERVICE Figure 5-16. µCEM Enclosure with door open. 5.9 Trouble LED The Red Trouble LED output is activated whenever there is a c

Página 21 - 2.1.2 Opto-Pneumatic Method

SOFTWARE 6. µCEM Software The µCEM Software includes 3 main components. One component is the µCEM control software that interfaces with the instrume

Página 22 - DETECTOR METHODOLOGIES

SOFTWARE uCEMControlSoftwareDevice DriversDigital andAnalog IOWebServerScriptSharedMemorySegmentData-Log& ConfigFilesHTML (TCP/IP)uCEM UserInterfa

Página 23 - 2.1.3 Overall NDIR Method

SOFTWARE 6.4 µCEM Pocket PC Connection Failure In the event of the connection with the µCEM failed, a connection failure dialog will be displayed. It

Página 24

PREFACE call: Model Number, Serial Number, and Purchase Order Number or Sales Order Number. Prior authorization by the factory must be obtained befor

Página 25

INTRODUCTION 1. Introduction 1.1 Overview This manual describes the Rosemount Analytical Micro Continuous Emission Monitoring (µCEM) gas Analyzer Mo

Página 26 - (Red) V out (Black)

INTRODUCTION Figure 1-1. µCEM Micro Continuous Emission Monitoring – Analysis Enclosure Rosemount Analytical µCEM Continuous Analyzer Transmitter 1

Página 27 - 3. Installation

INTRODUCTION Figure 1-2. µCEM Micro Continuous Emission Monitoring Gas Analyzer with Time Share option. 1.2 Time Shared Option Provides the function

Página 28 - INSTALLATION

INTRODUCTION TO SHU1CAL GASCAL GAS TO SHU2SAMPLE FROM SHU1 FROM SHU2SAMPLEEXHAUSTuCEM CALFROM TO uCEMSAMPLETV1TV2TV3TV4 Figure 1-3. Time Share option

Página 29

INTRODUCTION 1.3 Theory of Operation 1.3.1 NOx The NOx analyzer continuously analyzes a flowing gas sample for NOx [nitric oxide (NO) plus nitrogen

Página 30

INTRODUCTION 1.3.3 O2 Paramagnetic: The determination of oxygen is based on the measurement of the magnetic susceptibility of the sample gas. Oxygen

Página 31

INTRODUCTION 1.3.4 SO2 The optical bench can selectively measure multiple components in a compact design by using a unique dual optical bench design.

Página 32 - 3.2.1 Gas Conditioning

CONTENTS Preface Intended Use Statement …………………………………………………………………………….. 1 Safety Summary ……………………………………………………………………………………… 1 Specifications – Ana

Página 33

Detector Methodologies 2. Detector Methodologies The µCEM can employ up to three different measuring methods depending on the configuration chosen.

Página 34 - 3.3 Installation

DETECTOR METHODOLOGIES Figure 2-1. Absorption Bands of Sample Gas and Transmittance of Interference Filters 2.1.2 Opto-Pneumatic Method In the opto-p

Página 35

DETECTOR METHODOLOGIES Absorption chamber Figure 2-2. Opto-Pneumatic Gas Detector When the infrared radiation passes through the open

Página 36

DETECTOR METHODOLOGIES 2.1.3 Overall NDIR Method In the case of dual-channel analyzers, the broadband emission from two infrared sources pass through

Página 37

DETECTOR METHODOLOGIES 2.2 Paramagnetic Oxygen Method The paramagnetic principle refers to the induction of a weak magnetic field, parallel and propor

Página 38

DETECTOR METHODOLOGIES 2.3 Electrochemical Oxygen Method The electrochemical method of determining oxygen concentration is based on the galvanic cell

Página 39

DETECTOR METHODOLOGIES Figure 2-5 Reaction of Galvanic Cell Summary reaction O2+ 2 Pb → 2 PbO O2 + 4 H + 4 e → 2 H2O 2 Pb + 2 H2O → 2PbO + 4 H +

Página 40

INSTALLATION 3. Installation WARNING: ELECTRICAL SHOCK HAZARD Installation and servicing of this device requires access to components which may pres

Página 41

INSTALLATION Figure 3-1. Dimensional Drawing, Door closed. Shown with Time Share option. Rosemount Analytical µCEM Continuous Analyzer Transmitter

Página 42

INSTALLATION O2 IN CAL GASIN (CUST){ O2 IN INST AIR BY CUST DRAIN TO SAFE PRES ATMOS PLACE CONNECTIONS ELECTRICAL OUTCAL GASPLACE CUST INST BY AIR AT

Página 43 - 3.3.5 Analytical Leak Check

CONTENTS 4.2.5 µCEM Login...4-8 4.2

Página 44

INSTALLATION 2DRAINOUTINRC1APR1PI1ADJUST FOR20-30 PSIGSV11/4SSBH/534SLOPESLOPE1/2 NPT MALE1SAMPLE FLOWSP1RV1EOV1BLOWBACKSAMPLE CALIB710101010101010661

Página 45

INSTALLATION Analysis Enclosure Critical settings and control:1. Set MicroCEM Pressure guage (P1)to 5 psig +/- 0.5psig. Pressure set by BPR located

Página 46 - 4. Startup and Operation

INSTALLATION Figure 3-5. Gas Connections 1 – Sample Gas Inlet (From Probe) 2 – Calibration Gas (From Probe) 3 – Gas 3 Inlet (Cal Gas) 4 – Gas 2 Inlet

Página 47 - 4.2 Analyzer Operation

INSTALLATION values computer by the detectors will then be corrected to eliminate erroneous measurements due to changes in barometric pressure. The ga

Página 48 - 4.2.2 µCEM Main Window

INSTALLATION 3.3 Installation WARNING: ELECTRICAL SHOCK HAZARD Care should be taken if hazardous gases are to be measured or used for calibration. R

Página 49

INSTALLATION J1AC POWER INPUTJ2CPU I/O J3COM J4LAN J5EXT I/O J6SHU 1 J7SHU 2 J8SSU Figure 3-6 Electrical Connections J1 – AC Power Input J2 –

Página 50 - CEM Menus

INSTALLATION Figure 3-7. Circular Connector Assembly Instructions Rosemount Analytical µCEM Continuous Analyzer Transmitter 3–3

Página 51

INSTALLATION 3.3.4.2 EXT I/O Interface Connector (J5) - MicroCEM inputs and outputs are specific for customer use. The Analog Interface connector ha

Página 52 - CEM Alarms

INSTALLATION 94 Spare VIO 22 32 Shutdown1+ BLK 22 33 Shutdown1- ShutDown, Stream#1 Mode (Wet contact) GRY 22 Digital Input / Twisted Pair wire 34

Página 53 - Table 4-2 – Alarm Summary

INSTALLATION 3.3.4.3 SHU #1 / #2 Interface Connector (J6 & J7). These wires are to be connected directly to the MicroCEM sample handling enclos

Página 54 - CEM Login

CONTENTS 5.6.4.1 Features... 5-

Página 55 - Log off button

INSTALLATION 3.3.4.4 COM Interface Connector (J3) – Pocket PC external connection The COM Interface connector has a shell size of 10, 13 contacts.

Página 56

INSTALLATION J VSYNC BLACK CENTER K GND BLACK SHIELD L DATA DCC DATA M CLK DCC CLK N KBDATA KEYBOARD DATA P KBCLK KEYBOARD CLOCK R GND GROUND S

Página 57 - CEM Settings

INSTALLATION Figure 3-4. uCEM Analysis Enclosure interconnect diagramRosemount Analytical µCEM Continuous Analyzer Transmitter 3–3

Página 58 - STARTUP and OPERATION

INSTALLATION 3.3.5 Analytical Leak Check If explosive or hazardous gas samples are being measured with the µCEM, it is recommended that gas line fi

Página 59

INSTALLATION Figure 3-9. Leak Test Manometer Method Close the inlet shut-off valve and, following a brief period for pressure equilibrium, verify that

Página 60 - Military time type

INSTALLATION 3.3.5.3 Troubleshooting Leaks Liberally cover all fittings, seals, and other possible sources of leakage with a suitable leak test liquid

Página 61 - 4.3.4 µCEM Settings-Limits

INSTALLATION Rosemount Analytical µCEM Continuous Analyzer Transmitter 4–1 4. Startup and Operation 4.1 Startup Procedure Once the µCEM has been

Página 62

STARTUP and OPERATION Rosemount Analytical µCEM Continuous Analyzer Transmitter 4-1 Installation,” the analyzer is ready for operation. Before ope

Página 63

STARTUP and OPERATION Rosemount Analytical µCEM Continuous Analyzer Transmitter 4-2 1. Plug the external COM cable into J3 circular connector on

Página 64

STARTUP and OPERATION Rosemount Analytical µCEM Continuous Analyzer Transmitter 4-3 Table 4-1 - Status Values Shown in order of precedence. Maint

Página 65

PREFACE PREFACE INTENDED USE STATEMENT The µCEM Continuous Emission Monitoring Gas Analyzer is intended for use as an industrial process measu

Página 66 - 4.3.8 Auto Calibration

STARTUP and OPERATION Rosemount Analytical µCEM Continuous Analyzer Transmitter 4-4 4.2.3 µCEM Menus Lower left part of the µCEM screen contains t

Página 67 - CEM Administration

STARTUP and OPERATION Rosemount Analytical µCEM Continuous Analyzer Transmitter 4-5 Figure 4-2.2 - µCEM Tools Menu Figure 4

Página 68

STARTUP and OPERATION Rosemount Analytical µCEM Continuous Analyzer Transmitter 4-6 4.2.4 µCEM Alarms The µCEM Alarms dialog shows all the current

Página 69

STARTUP and OPERATION Rosemount Analytical µCEM Continuous Analyzer Transmitter 4-7 O2 High Limit Critical O2 Sensor reading is above the minima

Página 70

STARTUP and OPERATION Rosemount Analytical µCEM Continuous Analyzer Transmitter 4-8 4.2.5 µCEM Login The login dialog appears (Figure 4-4) when f

Página 71

STARTUP and OPERATION Rosemount Analytical µCEM Continuous Analyzer Transmitter 4-9 4.2.6 µCEM Login-Current User Indication When a user is logge

Página 72 - 4.6 uCEM Data Logs

STARTUP and OPERATION Rosemount Analytical µCEM Continuous Analyzer Transmitter 4-10 4.2.7 Stream Switching Control Typically a dual stream syste

Página 73

STARTUP and OPERATION Rosemount Analytical µCEM Continuous Analyzer Transmitter 4-11 4.3 µCEM Settings The µCEM Settings dialog is only available

Página 74

STARTUP and OPERATION Rosemount Analytical µCEM Continuous Analyzer Transmitter 4-12 Figure 4.6 - Range Settings The Tabs allow selection of the

Página 75 - 4.6.6 Alarm Log File Format

STARTUP and OPERATION Rosemount Analytical µCEM Continuous Analyzer Transmitter 4-13 4.3.2 µCEM Settings-Auto Calibration The Auto-Calibration se

Página 76

PREFACE DANGER: TOXIC GAS+WARNING: ELECTRICAL SHOCK HAZARDPOSSIBLE EXPLOSION HAZARDThis device may contain explosive, toxic or unhealthy gas compon

Página 77

STARTUP and OPERATION Rosemount Analytical µCEM Continuous Analyzer Transmitter 4-14 4.3.3 µCEM Settings - Auto Calibration Time and Frequency T

Página 78

STARTUP and OPERATION Rosemount Analytical µCEM Continuous Analyzer Transmitter 4-15 4.3.4 µCEM Settings-Limits The emission limits alarms can be

Página 79

STARTUP and OPERATION Rosemount Analytical µCEM Continuous Analyzer Transmitter 4-16 4.3.5 µCEM Settings-Calibration Gas The Calibration Gas valu

Página 80

STARTUP and OPERATION Rosemount Analytical µCEM Continuous Analyzer Transmitter 4-17 Figure 4.12 - Calibration Gas Settings

Página 81

STARTUP and OPERATION Rosemount Analytical µCEM Continuous Analyzer Transmitter 4-18 4.3.6 µCEM Settings-Maintenance Mode Maintenance mode may be

Página 82 - 4.8 Viewing

STARTUP and OPERATION Rosemount Analytical µCEM Continuous Analyzer Transmitter 4-19 4.3.7 µCEM -Manual Calibration A dry-run Calibration may be

Página 83

STARTUP and OPERATION 4.3.8 Auto Calibration The Auto Calibration dialog is displayed whenever calibration is in process. It displays the current emi

Página 84 - 4.8.2 Emissions Page

STARTUP and OPERATION 4.4 µCEM Administration The µCEM Administration dialog is only available to users with µCEM Administration permission. If a use

Página 85

STARTUP and OPERATION 4.4.2 µCEM Administration-Auto Logoff The number of minutes of inactivity after which a user is automatically logged off is set

Página 86

STARTUP and OPERATION 4.5 µCEM Factory and User Settings A µCEM Factory and User Settings files are available for use by µCEM technicians to set para

Página 87 - 4.8.3 Download Page

PREFACE WARNING: PARTS INTEGRITY AND UPGRADES Tampering with or unauthorized substitution of components may adversely affect the safety of this inst

Página 88 - CEM Data with MS Excel

STARTUP and OPERATION Table 4.3 - [General] section Calibration Setting Description Stream1Time Stream 1 processing time in minutes when auto swit

Página 89 - 5. Maintenance and Service

STARTUP and OPERATION Table 4.4 - [Stream X] section Stream Setting Description DiluentCorrectionPercent Diluent Correction Percent used in calc

Página 90

STARTUP and OPERATION R12O2SpanDriftLimit O2 Allowed Span Drift Limit for Range 2. R2COSpanDriftLimit CO Allowed Span Drift Limit for Range 2. R2NOX

Página 91 - 5.4 Personality Modules

STARTUP and OPERATION 4.6.4 Measurement Log File Format The log file contains data in a flat, ASCII, CSV file. The following are the fields of the f

Página 92

STARTUP and OPERATION Span calibration O2 R1 Mid Drift Percent drift of O2 Range 1 mid calibration. 0.4 O2 R1 Expected Span Expected percent O2 for

Página 93 - PHOTODIODE REMOVAL:

STARTUP and OPERATION NOx R2 Span Drift Percent drift of NOx Range 1 span calibration 0 NOx Expected R2 Mid Span Measured ppm NOx for Range 2 mid sp

Página 94 - PHOTODIODE INSTALLATION:

STARTUP and OPERATION 24 = Zone Cooler On Failed ** 25 = Zone Cooler Off Failed ** 26 = Heater Fan On Failed ** 27 = Heater Fan Off Failed ** 28 = Coo

Página 95

STARTUP and OPERATION 4.6.7 Accessing the Real-Time ACSII Data String via Ethernet TCP/IP (DAS) Remote Real-time data acquisition from the uCEM is d

Página 96 - 5.6 Central Processing Unit

STARTUP and OPERATION M – Maintenance C – Calibration P – Process Off O – uCEM Off AlarmsString – is a string data that describes the current Alarms

Página 97

STARTUP and OPERATION 4.7 Viewing Data via the Pocket PC Web Browser The Pocket PC Web Browser menu can be accessed via the pocket pc main menu. In

Página 98 - 16 differential

PREFACE SPECIFICATIONS - GENERAL SPECIFICATIONS – Analysis Enclosure: GENERAL Power: Universal Power Supply 85 – 125 VAC, 50 – 60 Hz, + 10%, 1000 W

Página 99

STARTUP and OPERATION zone may show than the AC/Heater unit fan may have failed or a possible defective thermocouple. *PDD Temp: For systems with NOx

Página 100

STARTUP and OPERATION Note: The Real-time, Config and Download are included in the navigation menu but these pages are intended for remote desktop use

Página 101 - 5.6.3 PCMCIA Adapter

STARTUP and OPERATION 4.8 Viewing µCEM Data with an external PC Web Browser The MicroCEM internal log files may be accessed using a user PC or laptop

Página 102 - 5.6.4 Modem

STARTUP and OPERATION Figure 4.18 - Real-Time Web Page Rosemount Analytical µCEM Continuous Analyzer Transmitter 4-2

Página 103 - Figure 5-11. Modem

STARTUP and OPERATION 4.8.2 Emissions Page The Emissions Page can be used to view emission history in a tabular web-page format. This page is used as

Página 104 - 5.6.5 Flash Drive

STARTUP and OPERATION Figure 4.20 - Emissions Table Rosemount Analytical µCEM Continuous Analyzer Transmitter 4-4

Página 105 - MAINTENANCE and SERVICE

STARTUP and OPERATION Figure 4.21 - Calibration Table Rosemount Analytical µCEM Continuous Analyzer Transmitter 4-5

Página 106

STARTUP and OPERATION 4.8.3 Download Page The download page of the µCEM allows the selection and download of the three types of Data-Logs. To quickly

Página 107 - 5.6.6 Pocket PC

STARTUP and OPERATION Figure 4.22 - Download Web Page Download Emissions Log, Calibration Log or Alarm Log Choose from: 1 Minute / 8 Hours 1 Minute /

Página 108 - 5.6.7 Wireless LAN Adapter

MAINTENANCE and SERVICE 5. Maintenance and Service CAUTION: QUALIFIED PERSONNEL This equipment should not be adjusted or repaired by anyone except pr

Página 109

PREFACE Digital Outputs: Following are connected directly to the MicroCEM Probe/Sample Handling Box: Sample Pump on/off, Drain Pump on/off, Pur

Página 110 - WARNING: PARTS INTEGRITY

MAINTENANCE and SERVICE Figure 5-2. uCEM Interconnect Diagram Rosemount Analytical µCEM Continuous Analyzer Transmitter 5-2

Página 111 - PARTS LIST

MAINTENANCE and SERVICE 5.2 Converter Refer to Figure 5-1, Item 97, and Figure 5-3. To replace the converter or sensor, disconnect the two pneumatic

Página 112 - CRAWFORD/SWGLO

MAINTENANCE and SERVICE Figure 5-4. Personality Modules and Backplane. Rosemount Analytical µCEM Continuous Analyzer Transmitter 5-4

Página 113

MAINTENANCE and SERVICE 5.5 Detector Assembly Refer to Figure 5-5 and Figure 5-6. REACTION CHAMBER REMOVAL: Disconnect the stainless steel tubing lin

Página 114

MAINTENANCE and SERVICE washers from the bracket. Remove the bracket, insulating disk and bottom plate as a unit to minimize the spread of the heatsin

Página 115 - 3130-F212-P7T1-S120

MAINTENANCE and SERVICE Figure 5-6. Detector Assembly O-Ring 854540Sapphire WindowCushioning GasketTubing CoverHeater*Heater*Thermostat*M3X0.5 x 16mm

Página 116 - 5.9 Trouble LED

MAINTENANCE and SERVICE 5.6 Central Processing Unit The CPU is an Embedded Pentium-type AT Computer in 5.75” x 8” form factor. The peripherals integr

Página 117 - 6. µCEM Software

MAINTENANCE and SERVICE 2 USB ports 4 RS232 serial ports (one can be 485) Parallel port (bi-directional EPP-ECP) Keyboard PS/2 Mouse PS/2 Bus:

Página 118

MAINTENANCE and SERVICE Figure 5-9. ADIO Block Diagram 5.6.2.1 Automatic Calibration The ADIO board features automatic calibration of both analog inp

Página 119

MAINTENANCE and SERVICE 5.6.2.3 Programmable Input Ranges A programmable gain amplifier, programmable unipolar/bipolar range, and programmable 5V/10V

Comentários a estes Manuais

Sem comentários