Emerson LC 320EM1 Manual de Serviço Página 13

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 12
3-4 TVN_SN
Instructions for Handling Semi-
conductors
Electrostatic breakdown of the semi-conductors may
occur due to a potential difference caused by
electrostatic charge during unpacking or repair work.
1. Ground for Human Body
Be sure to wear a grounding band (1 M) that is
properly grounded to remove any static electricity that
may be charged on the body.
2. Ground for Workbench
Be sure to place a conductive sheet or copper plate
with proper grounding (1 M) on the workbench or
other surface, where the semi-conductors are to be
placed. Because the static electricity charge on
clothing will not escape through the body grounding
band, be careful to avoid contacting semi-conductors
with your clothing.
<Incorrect>
CBA
Grounding Band
Conductive Sheet or
Copper Plate
1M
1M
<Correct>
CBA
Vista de página 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18 ... 136 137

Comentários a estes Manuais

Sem comentários