Reference Manual
00809-0100-4801, Rev FA
October 2010
A-39
Rosemount 3051S Series
Table A-4. Housing Kit for Rosemount 3051S Series Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Model Transmitter Type
300S Housing for 3051S Scalable Pressure Transmitter
Code Housing Style Material Conduit Entry Size
Standard Standard
1A PlantWeb housing Aluminum
1
/2–14 NPT ★
1B PlantWeb housing Aluminum M20 x 1.5 ★
1J PlantWeb housing SST
1
/2–14 NPT ★
1K PlantWeb housing SST M20 x 1.5 ★
2A Junction Box housing Aluminum
1
/2–14 NPT ★
2B Junction Box housing Aluminum M20 x 1.5 ★
2E Junction Box housing with output for remote interface Aluminum
1
/2–14 NPT ★
2F Junction Box housing with output for remote interface Aluminum M20 x 1.5 ★
2J Junction Box housing SST
1
/2–14 NPT ★
2M Junction Box housing with output for remote interface SST
1
/2–14 NPT ★
3A Remote mount display and interface housing Aluminum
1
/2–14 NPT ★
3B Remote mount display and interface housing Aluminum M20 x 1.5 ★
3J Remote mount display and interface housing SST
1
/2–14 NPT ★
7J
(1)
Quick Connect (A size Mini, 4-pin male termination) SST ★
Expanded
1C PlantWeb housing Aluminum G
1
/2
1L PlantWeb housing SST G
1
/2
2C Junction Box housing Aluminum G
1
/2
2G Junction Box housing with output for remote interface Aluminum G
1
/2
3C Remote mount display and interface housing Aluminum G
1
/2
Code Transmitter Output
Standard Standard
A 4-20 mA with digital signal based on HART protocol ★
F
(2)
FOUNDATION fieldbus protocol ★
Options (Include with selected model number)
PlantWeb Control Functionality
Standard Standard
A01 FOUNDATION fieldbus Advanced Control Function Block Suite ★
PlantWeb Diagnostic Functionality
Standard Standard
D01 FOUNDATION fieldbus Diagnostics Suite ★
DA2
(3)
Advanced HART Diagnostics Suite ★
Hardware Adjustments
Standard Standard
D1
(4)
Hardware adjustments (zero, span, alarm, security)
Note: Not available with Housing Style codes 2E, 2F, 2G, 2M, 3A, 3B, 3C, 3J, or 7J.
★
Conduit Plug
Standard Standard
DO 316 SST Conduit Plug ★
Product Certifications
Standard Standard
E1 ATEX Flameproof ★
I1 ATEX Intrinsic Safety ★
IA ATEX FISCO Intrinsic Safety (FOUNDATION fieldbus protocol only) ★
N1 ATEX Type n ★
K1 ATEX Flameproof, Intrinsic Safety, Type n, Dust ★
ND ATEX Dust ★
E5 FM Explosion-proof, Dust Ignition-proof ★
I5 FM Intrinsically Safe, Division 2 ★
IE FM FISCO Intrinsically Safe (FOUNDATION fieldbus protocol only) ★
Comentários a estes Manuais