How to Assign a MODBUS Address Parameters • 11
LOP Lowest operating pressure (PA4 to P20 bar/ psi)
If the suction pressure comes down to this value, a low pressure alarm is
signaled with Low Pressure alarm LED (related to PrM parameter).
PHY Pressure alarm hysteresis (0.1 to 5.0 bar/ 1 to 72 PSI)
Alarm hysteresis to disable alarm signaling.
dML delta MOP-LOP (0 to 100%)
When a MOP alarm occurs, the valve will close at the dML percentage
every one second until the MOP alarm is active. When LOP occurs, the
valve will open at the dML percentage every one second until LOP
alarm is active.
MSH Maximum superheat alarm (LSH to 32.0°C/ LSH to 176°F)
When the superheat exceeds this value, a high superheat alarm is sig-
naled after interval SHd.
LSH Lowest superheat alarm (0.0 to MSH°C/ 32 to MSH°F)
When the superheat goes down to this value, a low superheat alarm is
signaled after interval SHd.
SHy Superheat alarm hysteresis (0.0 to 25.5°C/ 1 to 77°F)
Hysteresis for superheat alarm deactivation.
SHd Superheat alarm activation delay (0 to 255 sec)
When a superheat alarm occurs, the time SHd has to pass before signal-
ing alarm.
FrC Fast-recovery constant (0 to 100 sec)
Increases the integral time when SH is below the setpoint. If FrC = 0,
fast-recovery function is disabled.
DISPLAY
Lod Local display Display: (SH, PEr, P1, P2)
SH = superheat; PEr = valve opening percentage; P1 = value of temper-
ature measured; P2 = pressure measured by P2 probe;
CF Temperature measurement units (°C to °F)
°C = Celsius degree; °F = Fahrenheit degree
CAUTION! By changing the measurement unit, the regulation parame-
ters have to be changed correctly.
PMU Pressure measurement units (bAr, PSI)
bAr = bar; PSI = psi
CAUTION! By changing the measurement unit, the regulation parame-
ters have to be changed correctly.
rES Resolution (only °C) (dE to in)
Whether a whole number or decimal point is used in temperature reading
PrM Pressure visualization mode (rEL to AbS)
rEL = relative pressure; AbS = absolute pressure
All pressure parameters depend on this parameter.
CLP Cooling percentage (Read only)
Displays the percentage of time during which the cooling call was active
in the time interval defined by parameter CLt.
tP1 Temperature probe value (Read only)
Shows the temperature probe value from P1.
PPr Pressure probe value (Read only)
Shows the pressure probe value. The value depends on PrM.
tP2 Temperature from P2 Shows the temperature obtained from conversion of pressure value.
Code Description Function
Table 8-1 - List of Parameters
Vista de página 16
1 2 ... 12 13 14 15 16 17 18 19 20 21 22 ... 29 30

Comentários a estes Manuais

Sem comentários

Radio Shack LK-1500 manuals

Owner’s manuals and user’s guides for Keyboards Radio Shack LK-1500.
We providing 2 pdf manuals Radio Shack LK-1500 for download free by document types: User Manual, Owner's Manual


Radio shack LK-1500 User Manual (80 pages)


Brand: Radio-shack | Category: Keyboards | Size: 4.31 MB |

 

Table of contents

Manual del Propietario

1

649U-S-002A

2

Precauciones de seguridad

3

ADVERTENCIA

4

PRECAUCIÓN

5

Características principales

7

649U-S-008A

8

649U-S-009A

9

Guía general

10

Indicadores del controlador

11

Referencia rápida

13

Fuente de alimentación

15

Usando el adaptador de CA

16

Desactivación automática

16

Alerta de activación de

17

Contenidos de la memoria

17

Conexiones

18

Pedal de sordina

19

Conectando a un aparato de TV

19

Operaciones básicas

20

Polifonía

21

Muestreo digital

21

Para usar PIANO SONGS

22

Aparece el indicador

22

PREPARACIÓN

23

Para reproducir una melodía

24

PIANO SONGS

24

Ajustando el tempo

24

649U-S-025A

25

Lección de 3 pasos avanzada

27

Modo de evaluación

28

Resultados de evaluación

29

Guía de digitación por voz

32

Usando el metrónomo

32

Usando la toma de micrófono

33

Seleccionando un ritmo

35

Ejecutando un ritmo

36

Usando el acompañamiento

36

FINGERED

37

FULL RANGE CHORD

38

Usando un patrón de relleno

39

Usando una variación de ritmo

39

Destello

40

Partes y pistas

41

649U-S-042A

42

Grabando una ejecución

43

¡IMPORTANTE!

44

Datos de la pista 1

45

Copiando una grabación de

46

Borrando una parte/pista

46

Ajustes del teclado

47

Usando la división

48

Transposición del teclado

49

Usando la respuesta al toque

50

Acom Vo l

51

Conexión a una computadora

52

Cambiando los ajustes

53

Sonidos de la MIDI general

53

CONTROL LOCAL

54

SALIDA DE ACOMPAÑAMIENTO

54

Recepción del modo GM

54

Mensajes

55

PROGRAM CHANGE

56

PITCH BEND

56

CONTROL CHANGE

56

ALL SOUND OFF

57

ALL NOTES OFF

57

RESET ALL CONTROLLERS

57

SYSTEM EXCLUSIVE*

57

Contactos

58

Area de protección

58

Botones numéricos

58

SmartMedia

59

Precauciones con la tarjeta

59

Forma t ?

60

Compartimiento de memoria

61

Usando una tarjeta SmartMedia

62

Solución de problemas

64

Especificaciones

66

Cuidado de su teclado

68

Apéndice

69

Lista de asignaci

74

Cuadro de acordes digitados

75

Lista de ritmos

76

Lista PIANO SONGS

77

Model

78

Version: 1.0

78

649U-S-079A

79

Garantía limitada de un año

80

RadioShack Corporation

80

Fort Worth, Texas 76102

80





More products and manuals for Keyboards Radio Shack

Models Document Type
LK-1161 Specifications   Radio Shack LK-1161 Specifications, 16 pages