Vista de página 0
www.rosemount.com
¢00825-0100-4716/¤
Quick Installation Guide
00825-0100-4716, Rev DA
October 2009
Rosemount 3095 MultiVariable
Start
End
Step 1: Mount the Transmitter
Step 2: Transmitter Installation
Step 3: Software Installation
Step 4: Connect the Wiring and Power Up (HART or Fieldbus)
Step 5: Configure the Transmitter (HART or Fieldbus)
Step 6: Trim the Transmitter
Product Certifications
Rosemount 3095 MultiVariable
Mass Flow
Transmitter with HART
®
or FOUNDATION
Fieldbus Protocol
Rosemount 3095MF Series Flowmeter Transmitter
Product Discontinued
Vista de página 0
1 2 3 4 5 6 ... 31 32

Resumo do Conteúdo

Página 1 - Product Discontinued

www.rosemount.com¢00825-0100-4716/¤Quick Installation Guide00825-0100-4716, Rev DAOctober 2009Rosemount 3095 MultiVariableStartEndStep 1: Mount the Tr

Página 2 - IMPORTANT NOTICE

Quick Installation Guide00825-0100-4716, Rev DAOctober 2009Rosemount 3095 MultiVariable10STEP 3: SOFTWARE INSTALLATIONThe 3095 Engineering Assistant (

Página 3 - TRANSMITTER EXPLODED VIEW

Quick Installation Guide00825-0100-4716, Rev DAOctober 2009Rosemount 3095 MultiVariable11STEP 3 CONTINUED...Installing the HART ModemAfter installing

Página 4 - STEP 1: MOUNT THE TRANSMITTER

Quick Installation Guide00825-0100-4716, Rev DAOctober 2009Rosemount 3095 MultiVariable12STEP 4: CONNECT WIRING AND POWER UP (HART)STEP 4: CONNECT WIR

Página 5

Quick Installation Guide00825-0100-4716, Rev DAOctober 2009Rosemount 3095 MultiVariable13STEP 4: CONNECT WIRING AND POWER UP (FIELDBUS)Use the followi

Página 6

Quick Installation Guide00825-0100-4716, Rev DAOctober 2009Rosemount 3095 MultiVariable14STEP 5: CONFIGURE THE TRANSMITTER (HART)Setting the Loop to M

Página 7

Quick Installation Guide00825-0100-4716, Rev DAOctober 2009Rosemount 3095 MultiVariable15DP Sens Trim 1, 2, 2, 1, 1DP Snsr Range 1, 3, 5, 1DP URV 5DP

Página 8

Quick Installation Guide00825-0100-4716, Rev DAOctober 2009Rosemount 3095 MultiVariable16STEP 5: CONFIGURE THE TRANSMITTER (FIELDBUS)Each FOUNDATION f

Página 9

Quick Installation Guide00825-0100-4716, Rev DAOctober 2009Rosemount 3095 MultiVariable17STEP 6: TRIM THE TRANSMITTERNOTETransmitters are shipped from

Página 10 - STEP 3: SOFTWARE INSTALLATION

Quick Installation Guide00825-0100-4716, Rev DAOctober 2009Rosemount 3095 MultiVariable18PRODUCT CERTIFICATIONSRosemount 3095 with HARTApproved Manufa

Página 11 - OUNDATION Fieldbus

Quick Installation Guide00825-0100-4716, Rev DAOctober 2009Rosemount 3095 MultiVariable19Canadian Standards Association (CSA) C Explosion Proof for Cl

Página 12 - Rosemount 3095 MultiVariable

Quick Installation Guide00825-0100-4716, Rev DAOctober 2009Rosemount 3095 MultiVariable2© 2009 Rosemount Inc. All rights reserved. All marks property

Página 13

Quick Installation Guide00825-0100-4716, Rev DAOctober 2009Rosemount 3095 MultiVariable20G ATEX Type n Certificate Number: BAS98ATEX3360X II 3 GEx n

Página 14

Quick Installation Guide00825-0100-4716, Rev DAOctober 2009Rosemount 3095 MultiVariable21The capacitance and either the Inductance or the Inductance t

Página 15

Quick Installation Guide00825-0100-4716, Rev DAOctober 2009Rosemount 3095 MultiVariable22China (NEPSI) Certifications2 China Intrinsic SafetyEx ia IIC

Página 16

Quick Installation Guide00825-0100-4716, Rev DAOctober 2009Rosemount 3095 MultiVariable2311.When installation, use and maintenance transmitter, observ

Página 17 - STEP 6: TRIM THE TRANSMITTER

Quick Installation Guide00825-0100-4716, Rev DAOctober 2009Rosemount 3095 MultiVariable24Combinations of CertificationsStainless steel certification t

Página 18 - PRODUCT CERTIFICATIONS

Quick Installation Guide00825-0100-4716, Rev DAOctober 2009Rosemount 3095 MultiVariable25Rosemount 3095 Fieldbus Hazardous Locations Certifications No

Página 19

Quick Installation Guide00825-0100-4716, Rev DAOctober 2009Rosemount 3095 MultiVariable26 Special conditions for safe use (x):Versions of the apparatu

Página 20

Quick Installation Guide00825-0100-4716, Rev DAOctober 2009Rosemount 3095 MultiVariable27P ATEX DustCertificate Number: KEMA02ATEX2321 II 1 D T90°C (-

Página 21

Quick Installation Guide00825-0100-4716, Rev DAOctober 2009Rosemount 3095 MultiVariable287 IECEx FlameproofCertificate Number: IECEx KEM 06.0018Zone 0

Página 22

Quick Installation Guide00825-0100-4716, Rev DAOctober 2009Rosemount 3095 MultiVariable29

Página 23

Quick Installation Guide00825-0100-4716, Rev DAOctober 2009Rosemount 3095 MultiVariable3TRANSMITTER EXPLODED VIEWHousingO-ringCoverHousing Locking Scr

Página 24

Quick Installation Guide00825-0100-4716, Rev DAOctober 2009Rosemount 3095 MultiVariable30

Página 25

Quick Installation Guide00825-0100-4716, Rev DAOctober 2009Rosemount 3095 MultiVariable31

Página 26

Quick Installation Guide00825-0100-4716, Rev DAOctober 2009Rosemount 3095 MultiVariable32

Página 27

Quick Installation Guide00825-0100-4716, Rev DAOctober 2009Rosemount 3095 MultiVariable4STEP 1: MOUNT THE TRANSMITTERFigure 1. Using a Mounting Brack

Página 28

Quick Installation Guide00825-0100-4716, Rev DAOctober 2009Rosemount 3095 MultiVariable5STEP 2: TRANSMITTER INSTALLATIONConsider Housing RotationTo im

Página 29

Quick Installation Guide00825-0100-4716, Rev DAOctober 2009Rosemount 3095 MultiVariable6STEP 2 CONTINUED...3. Set the Failure Mode Alarm (HART devices

Página 30

Quick Installation Guide00825-0100-4716, Rev DAOctober 2009Rosemount 3095 MultiVariable7STEP 2 CONTINUED...• Installing a Shielded 3095 RTD Cable (See

Página 31

Quick Installation Guide00825-0100-4716, Rev DAOctober 2009Rosemount 3095 MultiVariable8STEP 2 CONTINUED...Bolting ConsiderationsIf the transmitter in

Página 32

Quick Installation Guide00825-0100-4716, Rev DAOctober 2009Rosemount 3095 MultiVariable9STEP 2 CONTINUED...Figure 7. Torque values for the flange and

Comentários a estes Manuais

Sem comentários