Liebert Condensers And Drycoolers
All Components From
One Manufacturer
Emerson Network Power is the only
manufacturer in the computer support
industry that builds its own condensers and
drycoolers. Liebert condensers and drycoolers
feature aluminum cabinets and copper-tube,
aluminum-fin coils, and are built to precisely
match the heat rejection requirements of the
Liebert Challenger 3000.
7
Wide range of heat rejection solutions
vertical or horizontal airflows, indoor or
outdoor models, freestanding or ducted
configurations.
Standard units—Sized for maximum
outdoor ambient temperatures of 85 °F
(29.4°C) to 105°F (40.6°C).
Liebert VFD Control Condenser—Features
a variable frequency drive (VFD) and an
inverter duty fan motor with ceramic
bearings. The VFD control uses pressure
transducers to modulate the condenser
fan motor speed to hold condensing
temperatures constant. This system allows
for operation at ambient temperatures as
low as -20°F (-28.9°C).
Fan Speed Control Condenser—A fan-
speed control varies the variable speed
fan motor based on compressor head
pressure to maintain constant condensing
temperatures. This system allows for
operation at ambient temperatures as low
as -20°F (-28.9°C).
Lee-Temp Condenser—The Lee-Temp
winter control system’s heated receivers
permit startup and positive head pressure
control at ambient temperatures as low as
-30°F (-34.4°C).
Drycoolers, Pumps, Tanks and Controls
Complete heat rejection solutions for
glycol-cooled and GLYCOOL units consist of
drycoolers, glycol pumps, expansion tanks
and integral or separate pump electrical
control boxes.
Quiet-Line
Condenser/Drycooler
Operate with the lowest noise level of any
heat rejection available, offering levels of
less than 57 dBA.
Indoor Piggyback Condenser/Drycooler
Indoor condensers/drycoolers designed to
provide heat rejection by ducting air from
outside the building, such as
high-rise buildings.
High Ambient Condensers—Utilize
increased coil surfaces for operation in
outdoor climates up to 120 °F (48.9 °C).
Prop Fan Condensing Units for Air Cooled
split systems — operate with quiet, high
efficiency scroll compressor. The units run
efficiently even at partial load conditions.
Fully wired, piped and tested. Outdoor
mounting. Allows operation down to
ambient temperatures as low as
-30°F (-34.4°C).
Centrifugal Fan Condensing Units for
Air Cooled split systems —operate with
quiet, high efficiency scroll compressor.
The units run efficiently even at partial load
conditions. Fully wired, piped and tested.
Indoor mounting.
Water/Glycol Condensing Units for
Water/Glycol Cooled split systems—
operate with quiet, high efficiency scroll
compressor. The units run efficiently even
at partial load conditions. Fully wired, piped
and tested. Indoor mounting.
For Ultimate
Energy Efficiency:
GLYCOOL™
The GLYCOOL system is a patented
Liebert fluid economizer that allows
colder outdoor temperatures to reduce
or eliminate compressor operation,
without the risk of outside pollutants or
contaminants. This reduces operating
costs and increases reliability.
When outdoor temperatures
are above room temperature,
the GLYCOOL Liebert Challenger
functions as a normally glycol-
cooled system. But when outdoor
temperatures fall below room
temperatures, the glycol that
circulates between the condenser
and drycooler becomes cold
enough to provide some or all
of the room’s cooling needs.
The cold glycol is redirected to a
supplemental cooling coil by means
of a microprocessor-controlled
valve, providing the same cooling
capacity as the mechanical
refrigeration system.
Liebert
drycooler
Glycol-cooled
condensers
Compressor
Glycol
circulating
pump
Integrated
Glycool coil