PMC-CGM Installation and Use (6806800D53C)
Access and Configuration Cabling
36
4.2.1 Cabling
To access the PMC-CGM, you have to attach an Ethernet cable to the ARTM-F103-STX as
shown in the following graphic.
It is mandatory that you connect port ETH7 with ETHA on the same ARTM-F103-STX and that
you cross-connect ETH8 with ETHB on the peer ARTM-F103-STX as indicated below.
4.2.2 Access
To access the module you can either use IPMI or a MIB browser.
For details on how to access the module via IPMI refer to the PMC-CGM: Control via IPMI
Programmer’s Reference.
When using a MIB browser, you have to specify the settings described in Using a MIB Browser
on page 37.
Figure 4-1 Connecting the ARTM-F103-STX Ethernet Ports