Emerson ASCO 336 Series Paralleling System Manual do Operador

Consulte online ou descarregue Manual do Operador para Detetores de fumo Emerson ASCO 336 Series Paralleling System. Emerson ASCO 336 Series Paralleling System Operator's Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 16
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
Operator’s Manual ASCO 336 / 337
381333-427 A ASCO Power Technologies Page 1
DANGER is used in this manual to warn of a
hazard situation which, if not avoided, will result in
death or serious injury.
WARNING is used in this manual to warn of a
hazardous situation which, if not avoided, could
result death or serious injury.
CAUTION is used in this manual to warn of a
hazardous situation which, if not avoided, could
result in minor or moderate injury.
Rating Label
Each 336/337 PCS contains a rating label to define the loads
and fault circuit withstand/closing ratings. Refer to the label
on the transfer switch for specific values.
In a non-redundant system, that is, the load current is more
than one generator’s full load current and the generators are
being paralleled to provide more power to the load, the CTTS
current rating must be equal to or greater than the sum of the
two generator’s full load amps.
If the application is a redundant system, that is, the load
current is equal to or less than the full load amps of one
generator and the generators are being paralleled for
redundancy, the 336 or 337 rating must be equal to or greater
than the full load current of the biggest generator. In addition,
the output of the CTTS unit must be protected by an over
current device, like a circuit breaker, equal to or less than the
CTTS rating label.
Do not exceed the values on the rating label.
Exceeding the rating can cause personal injury or
serious equipment damage.
381333-427 A
DANGER
!
WARNING
!
CAUTION
!
300 Series Power Control System
336 /337 Generator Paralleling System
Operator’s Manual
INSTALLATION ............................................... 3
FUNCTIONAL TEST .................................... 5-8
OPERATIONAL TESTING ........................ 9-10
FEATURES & OPTIONS ......................... 11-13
PROTECTIVE RELAY FUNCTIONS ............. 14
TESTING & SERVICE ................................... 15
INDEX ............................................................ 16
Table of Contents
page
WARNING
!
Refer to the outline and wiring drawings provided
with the 336 / 337 for all installation and connection
details and accessories.
Refer to the Controller User’s Guide for status
display messages, time delays, pickup and dropout
settin
g
s, and ad
j
ustments.
Vista de página 0
1 2 3 4 5 6 ... 15 16

Resumo do Conteúdo

Página 1 - Operator’s Manual

Operator’s Manual ASCO 336 / 337 381333-427 A ASCO Power Technologies Page 1 DANGER is used in this manual to warn of a hazard situation w

Página 2

ASCO 336 / 337 Operator’s Manual Page 10 ASCO Power Technologies 381333-427 A Load Bus Ready for First Generator CTBx: 11,12, First CTTS Close E

Página 3 - Installation

Operator’s Manual ASCO 336 / 337 381333-427 A ASCO Power Technologies Page 11 Figure 8. Emergency Stop buttons for generators. Featur

Página 4 - Gen1 is CTB1, Gen 2 is CTB2

ASCO 336 / 337 Operator’s Manual Page 12 ASCO Power Technologies 381333-427 A Load Management or Load Shed / Load Add will work in cooperation wi

Página 5 - Functional Test

Operator’s Manual ASCO 336 / 337 381333-427 A ASCO Power Technologies Page 13 Run Time Management or Run Time Equalization Run Time Management

Página 6

ASCO 336 / 337 Operator’s Manual Page 14 ASCO Power Technologies 381333-427 A Protective relay functions Most protective functions will open the

Página 7

Operator’s Manual ASCO 336 / 337 381333-427 A ASCO Power Technologies Page 15 Testing & Service Transfer Test Operate the transfer switch at

Página 8

ASCO 336 / 337 Operator’s Manual Page 16 ASCO Power Technologies 381333-427 A INDEX A ASI is ASCO Services Inc. 800-800-2726(ASCO) customercare

Página 9 - Mode Selection

ASCO 336 / 337 Operator’s Manual Page 2 ASCO Power Technologies 381333-427 A 300 Series PCS Family of Products The ASCO 300 Series Power Control

Página 10

Operator’s Manual ASCO 336 / 337 381333-427 A ASCO Power Technologies Page 3 Automatic Control System The 336 / 337 is an automatic control syste

Página 11 - Features and Options

ASCO 336 / 337 Operator’s Manual Page 4 ASCO Power Technologies 381333-427 A Generator Circuit Breaker Control Circuits The generator circuit bre

Página 12

Operator’s Manual ASCO 336 / 337 381333-427 A ASCO Power Technologies Page 5 Functional Test The functional test consists of three checks: manua

Página 13

ASCO 336 / 337 Operator’s Manual Page 6 ASCO Power Technologies 381333-427 A Figure 3. H-design Transfer Switch Ma

Página 14 - Protective relay functions

Operator’s Manual ASCO 336 / 337 381333-427 A ASCO Power Technologies Page 7 Figure 5. Buttons and indicator lights on g

Página 15 - Testing & Service

ASCO 336 / 337 Operator’s Manual Page 8 ASCO Power Technologies 381333-427 A Figure 6. Button and indicator lights on generator

Página 16

Operator’s Manual ASCO 336 / 337 381333-427 A ASCO Power Technologies Page 9 Figure 7. Operator Interface Terminal (OIT) with Power Managemen

Comentários a estes Manuais