167D Series
Instruction Manual
Form 5859
June 2011
D103234X012
www. sherregulators.com
167D Series Switching Valves
TYPE 167D TWO-WAY SWITCHING VALVE TYPE 167DA THREE-WAY SWITCHING VALVE
Figure 1. 167D Series Switching Valves
!
WARNING
Failure to follow these instructions or
to properly install and maintain this
equipment could result in an explosion,
re and/or chemical contamination
causing property damage and personal
injury or death.
Fisher
®
switching valves must be
installed, operated, and maintained
in accordance with federal, state, and
local codes, rules, and regulations, and
Emerson Process Management Regulator
Technologies, Inc. instructions.
If the switching valve vents gas or a
leak develops in the system, service
to the unit may be required. Failure
to correct trouble could result in a
hazardous condition.
Installation, operation, and maintenance
procedures performed by unquali ed
personnel may result in improper
adjustment and unsafe operation. Either
condition may result in equipment
damage or personal injury. Use quali ed
personnel when installing, operating,
and maintaining the 167D Series
switching valves.
Introduction
Scope of the Manual
This manual provides instructions for the installation,
maintenance, and parts ordering for the 167D Series
Switching Valves. Instructions and parts lists for other
equipment mentioned in this instruction manual, as
well as for other switching valves are found in
separate manuals.
P1184P1185
Vista de página 0
1 2 3 4 5 6 ... 11 12

Resumo do Conteúdo

Página 1 - 167D Series Switching Valves

167D SeriesInstruction ManualForm 5859June 2011D103234X012www. sherregulators.com167D Series Switching ValvesTYPE 167D TWO-WAY SWITCHING VALVE TYPE

Página 2

167D Series10Figure 9. Type 167DS Assembly18192017451161511501233735058571448AAPPLY LUBRICANT (L)Figure 10. Type 167DAS AssemblyLAPPLY LUBRICANT (L)

Página 3

167D Series11Figure 13. Optional Closing Cap[Only Available with the 1/4 NPT Spring Case Vent]Figure 12. Types 167D and 167DS Diaphragm Assembly (Ke

Página 4

167D Series©Emerson Process Management Regulator Technologies, Inc., 2009, 2011; All Rights ReservedThe Emerson logo is a trademark and service mark o

Página 5

167D Series2SpecicationsSome general 167D Series switching valve ratings and other specications are given on this page. A label on the spring case

Página 6

167D Series3OUTLET PRESSURE (WHEN LOADING PRESSURE IS LESS THAN SETPOINT)INLET PRESSUREOUTLET PRESSURE (WHEN LOADING PRESSURE IS EQUAL TO OR GREATER T

Página 7

167D Series4Product DescriptionThe 167D Series switching valves are pneumatically operated and controlled units, built with a wide range of capabiliti

Página 8

167D Series5Figure 5. Typical Switching Valve SchematicFigure 4. Typical 167D or 167DS Installation (Warning system using Type 167D or 167DS two-way

Página 9

167D Series6 the lines or from external sources. Switching valves should be inspected for damage periodically and aft

Página 10 - 167D Series

167D Series7 4. Place the diaphragm assembly (key 16) on the body (key 1) as shown in Figures 7 through 10. Push down on the diaphragm ass

Página 11

167D Series8*Recommended Spare Parts Inconel® is a mark owned by Special Metals Corporation.Parts OrderingWhen corresponding with the local Sales Ofc

Página 12

167D Series9Figure 7. Type 167D Assembly1819201715501457716350115814812AAPPLY LUBBRICANT (L)GE37632Figure 8. Type 167DA AssemblySECTION B-BGF02289_B