1805 Series
D100345X012
Instruction Manual
Form 1211
October 2011
1805 Series Relief Valves
Failure to follow these instructions or
to properly install and maintain this
equipment could result in an explosion
and/or re causing property damage and
personal injury or death.
Fisher
®
relief valves must be installed,
operated and maintained in accordance
with federal, state, and local codes, rules
and regulations, and Emerson Process
Management Regulator Technologies,
Inc. instructions.
If a leak develops or if the outlet
continually vents gas, service to the unit
may be required.
Failure to correct trouble could result in
a hazardous condition. Only a qualied
person must install or service the unit.
Call a gas service person to service the
unit. Only a qualied person must install
or service the 1805 Series Relief Valves.
Introduction
Scope of the Manual
This Instruction Manual provides installation,
adjustment, maintenance, and parts ordering
information for 1805 Series relief valves.
Description
The 1805 Series relief valves are primarily designed
for use in farm tap applications where a safety relief
valve is needed between the rst and second stage
regulators. The 1805 Series is suitable for service on
Figure 1. 1805 Series Relief Valve
P1026
natural gas, air, propane, or any operating medium that
is not corrosive to the internal parts. Relief pressure
ranges from 5 to 125 psi / 0,34 to 8,6 bar. Maximum
pressure, including buildup, is 150 psi / 10,3 bar.
Specications
The Specications section lists the specications for
the 1805 Series relief valve. The following information
is stamped on the relief valve at the factory: type
number, date of manufacture, spring range, maximum
inlet pressure, and maximum allowable inlet pressure.
!
WARNING
www.sherregulators.com
Vista de página 0
1 2 3 4 5 6 7 8

Resumo do Conteúdo

Página 1 - 1805 Series Relief Valves

1805 SeriesD100345X012Instruction ManualForm 1211October 20111805 Series Relief ValvesFailure to follow these instructions or to properly install and

Página 2 - 1805 Series

1805 Series2SpecicationsAvailable ConstructionsType 1805-2 - Cast iron spring case, closing cap with 1/4 NPT vent placed over the adjusting screw. A

Página 3 - Type XXXX

1805 Series3Principle of OperationSee Figure 2. Relief valves respond to changes in upstream pressure. If upstream pressure increases and exceeds th

Página 4

1805 Series4InstallationAfter unpacking, check the relief valve for shipping damage. Remove pipe scale and other foreign material from the connecting

Página 5

1805 Series5OverpressureRelief pressure ratings are from 5 to 125 psi / 0,34 to 8,6 bar. The maximum inlet pressure, including buildup, is 150 psi /

Página 6

1805 Series6Figure 4. Type 1805-3 Relief Valve Assembly (Also typical of 1805 relief valves)BE9481_D17141513121819111091682453761

Página 7

1805 Series7Parts ListKey Description Part Number Parts kit (included are keys 3, 5, and 8) 3/4 and 1 NPT body sizes R1805X00012 1

Página 8

1805 Series©Emerson Process Management Regulator Technologies, Inc., 1975, 2011; All Rights ReservedThe Emerson logo is a trademark and service mark o

Comentários a estes Manuais

Sem comentários