Type 92B Pressure Reducing Valve
 
 
 
 
 
 
 
Figure 1. Type 92B Pressure Reducing Valve
W8264
Vista de página 0
1 2 3 4 5 6 ... 15 16

Resumo do Conteúdo

Página 1 - Bulletin 71.2:92B

Bulletin 71.2:92BSeptember 2014D101342X012www.fisherregulators.comType 92B Pressure Reducing Valve    

Página 2

Bulletin 71.2:92B10

Página 3

Bulletin 71.2:92B11Table 5. Main Valve Coefcients1 

Página 4

Bulletin 71.2:92B12Table 6. Capacities(1) (continued) 

Página 5

Bulletin 71.2:92B13     (1) and (1) and   Pressure 

Página 6

Bulletin 71.2:92B14 (Select One) ≤ 125 psig / 8.6 bar; 353°F / 178°C ≤ 175 psig / 12.1 bar; 450°F / 232°C

Página 7

Bulletin 71.2:92B15 15 to 100 psig / 1.0 to 6.9 bar, Unpainted 80 to 250 psig / 5.5 to 17.2 bar, Unpai

Página 8

Bulletin 71.2:92B©Emerson Process Management Regulator Technologies, Inc., 1980, 2014; All Rights ReservedThe Emerson logo is a trademark and service

Página 9

Bulletin 71.2:92B2The Type 92B Pressure Reducing Valve is the standard steam valve for industry. The Type 92B is designed to provide decad

Página 10

Bulletin 71.2:92B3Figure 2. Typical Type 92B Construction

Página 11

Bulletin 71.2:92B4This section lists the specications for the Type 92B Pressure Reducing Valve. The following information is stamped on

Página 12

Bulletin 71.2:92B5Table 1. Body Sizes and End Connection StylesTable 2. Outlet Pressure RangesTable 3. Maximum Inlet Pressures and TemperaturesTable 4

Página 13

Bulletin 71.2:92B6Figure 3. Type 92B Operational SchematicRefer to Figure 3. Compression of the pilot spring pushes diaphragm do

Página 14

Bulletin 71.2:92B7system, thereby preventing a high differential across the diaphragm which might otherwise cause diaphragm damage. The check valve cl

Página 15

Bulletin 71.2:92B8Installation of the Type 92B is dependent on the application. As a minimum, a typical steam pressure reducing station mu

Página 16

Bulletin 71.2:92B9

Comentários a estes Manuais

Sem comentários