Emerson 95 Series Pressure Reducing Regulators Manual de Instruções Página 4

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 12
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 3
Types 95LD and 95HD
4
Type 95HD Differential Pressure Reducing Regulator
M1006
INLET PRESSURE
OUTLET PRESSURE
October 2006
Type 95HD
LOADING PRESSURE



Type 95HD Differential Pressure Reducing Regulator
M1006
INLET PRESSURE
OUTLET PRESSURE
October 2006
Type 95HD
LOADING PRESSURE

Types 95LD and 95HD regulators maintain a differential
pressure between the loading supply pressure and the
downstream pressure of the regulator.
Refer to Figure 2. The design of the regulator isolates
the diaphragm and pressure response chamber from
the main ow stream. The downstream pressure
(outlet pressure) is registered under the diaphragm
through the pitot tube or registration hole. If the
downstream pressure increases, pressure under the
diaphragm also increases. This force overcomes
the spring compression and loading supply pressure,
allowing the stem to rise. The valve plug spring forces
the valve plug closer to the orice. Flow through the
regulator is reduced so that downstream pressure
returns to the desired differential level. When the
downstream pressure decreases, the opposite
action takes place. Pressure under the diaphragm
decreases. The valve stem pushes the valve plug
downward, opening the ow stream and increasing the
ow through the regulator. Downstream pressure rises
back to the desired differential level.

Before installing the regulator, be sure the chosen
location is adequately protected from damage by
vehicles and other external sources. The regulator
should be away from building eaves and above
probable snow levels. Temperature conditions should
not exceed the limits shown in Specications section.
Unpack the regulator and remove the protective
shipping plugs from the end connections of the
body and the pressure connection in the spring
case. Be sure the body and connecting pipelines
are clean. Coat the pipeline threads with a suitable
pipe compound. The regulator may be installed in
any position as long as the ow is in the direction
indicated by the arrow cast on the body.
The design of the regulator isolates the diaphragm
and the pressure response chamber from the main
ow steam. Outlet pressure registers under the
diaphragm through the pitot tube or registration
hole. Loading pressure registers on the top of the
diaphragm. The loading pressure is connected to the
NPT connection in the spring case.

!










The Types 95LD and 95HD have outlet pressure
ratings that are lower than the inlet pressure ratings.
Some type of overpressure protection is needed
if the actual inlet pressure can exceed the outlet
pressure rating. Common methods of overpressure
protection include relief valves, monitoring
regulators, or series regulation.
The maximum pressures that should not be exceeded
are stamped on the nameplate and are also shown in
the Specications section and Table 1.














W0078*
Figure 2. Type 95HD Operational Schematic
(Also Typical of 95LD)









Vista de página 3
1 2 3 4 5 6 7 8 9 10 11 12

Comentários a estes Manuais

Sem comentários