Specifications
Operating Pressure Range
See tables 3 and 4
Maximum Travel
Sizes P462 and P900: 120 mm (4.75 inches)
Size P460-200: 200 mm (8 inches)
Output Indication
Stainless steel disc or pointer and graduated scale
Stroking Speed
Dependent on actuator size, travel, spring rate, initial
spring compression, and supply pressure. If stroking
speed is critical, consult your Emerson Process
Management sales office
Operating Temperature Range
-30 to 80_C
Volumetric Displacement
See table 2
Signal Connection
1/2 NPT internal
Effective Diaphragm Area
See table 4
Maximum Pressure
4barg
Construction Materials
Diaphragm Casing: Steel
Diaphragm: Nitrile on nylon
Diaphragm Plate: Steel
Actuator Spring: Steel alloy
Actuator Stem: Steel alloy
Travel Indicator: Stainless steel
Yoke: Steel
Stem and Yoke Boss Diameters
ACTUATOR
SIZE
YOKE BOSS
DIAMETER
(Inches)
STEM DIAMETER
mm Inches
P462 and
P460-200
3-9/16
5
5H
(1)
19.1
25.4
31.8
3/4
1
1-1/4
P900
5
5H
(1)
25.4
31.8
1
1-1/4
1. H = Heavy actuator to valve bolting.
Dimensions and Weights
Seetables5,6,and7andfigures3,4,and5
Options
J Side-mounted gear handwheel, J Oversize signal
connections
Available Configurations
The 3025 actuator can be supplied in either direct or
reverse action.
Direct Action
In direct action, applying air pressure to the upper
diaphragm casing forces the actuator stem downward.
When this pressure is reduced, the opposing spring
forcemovestheactuatorstemupward.Shouldthe
loading pressure fail, the spring forces the stem to the
extreme upward position. This provides fail-open
action for push-down-to-close valves and fail-closed
action for push-down-to-open valves.
Reverse Action
In reverse action, applying air pressure to the lower
diaphragm casing forces the actuator stem upward
against the opposing spring force. When this loading
pressure is reduced, the spring moves the actuator
stem to the extreme downward position. Should the
loading pressure fail, the spring forces the stem to the
extreme downward position. Reverse acting actuators
provide fail-closed action for push-down-to-close
valves and fail-open action for push-down-to-open
valves.