10 Modbus
®
Mapping Assignments for Micro Motion
®
Transmitters
Modbus Mapping Assignments continued
3 0005 Volume flow rate scaled integer
ÖÖÖÖ
3 0008 Mass total scaled integer
ÖÖÖÖ
3 0009 Volume total scaled integer
ÖÖÖÖ
3 0010 Mass inventory scaled integer
ÖÖÖÖ
3 0011 Volume inventory scaled integer
ÖÖÖÖ
3 0016 Transmitter software revision (xxxx.x format; 141 = rev14.1)
ÖÖÖÖ
3 0045 Standard or special mass total or inventory unit
1
ÖÖÖÖ
3 0046 Standard or special volume total or inventory unit
2
ÖÖÖÖ
3 0120 Device type code
ÖÖÖÖ
3 0121 Electronics manufacturer’s code identification number
ÖÖÖÖ
3 0122 HART device I.D. number – high order register of 3-byte integer
ÖÖÖÖ
3 0123 HART device I.D. number – low order register of 3-byte integer
ÖÖÖÖ
3 0125 Bit #0 Primary mA output saturated
ÖÖÖ
Bit #1 Secondary mA output saturated
3
ÖÖ
Bit #2 Primary mA output fixed
ÖÖÖ
Bit #3 Secondary mA output fixed
1
ÖÖ
Bit #4 Density overrange
ÖÖÖÖ
Bit #5 Drive gain overrange
ÖÖÖÖ
Bit #6 Not used
Bit #7 External input error
Ö
Bit #8 (E)EPROM checksum failure, core processor or RFT9739
ÖÖÖÖ
Bit #9 RAM diagnostic failure, core processor or RFT9739
ÖÖÖÖ
Bit #10 Sensor failure
ÖÖÖÖ
Bit #11 Temperature sensor failure
ÖÖÖÖ
Bit #12 Input overrange
ÖÖÖÖ
Bit #13 Frequency/pulse output saturated
ÖÖÖ
Bit #14 Transmitter not configured
ÖÖÖÖ
Bit #15 Real-time interrupt failure
ÖÖÖÖ
3 0126 Bit #0 Burst mode enabled
ÖÖÖ
Bit #1 Power reset occurred
ÖÖÖÖ
Bit #2 Transmitter initializing/warming up
ÖÖÖÖ
Bit #3 Security breach
Ö
Bit #4 Display readback error
Ö
Bit #5 Event 2 ON
ÖÖÖÖ
Bit #6 Event 1 ON
ÖÖÖÖ
Bit #7 Not used
Bit #8 Flowmeter zeroing failure
ÖÖÖÖ
Bit #9 Zero value too low
ÖÖÖÖ
Bit #10 Zero value too high
ÖÖÖÖ
Bit #11 Zero too noisy
ÖÖÖÖ
Bit #12 Transmitter electronics failure
ÖÖÖÖ
Bit #13 Data loss possible
ÖÖÖÖ
Bit #14 Calibration in progress
ÖÖÖÖ
Bit #15 Slug flow
ÖÖÖÖ
3 0295 Security event configuration register
Ö
3 0296 Security event calibration register
Ö
3 0297 Mass flow live zero flow
Ö
4
3 0305 Most significant word for binary mass total
Ö
5
3 0306 High-order word for binary mass total
Ö
3
3 0307 Low-order word for binary mass total
Ö
3
3 0308 Least significant word for binary mass total
Ö
3
3 0309 Most significant word for binary volume total
Ö
3
Table 2-5. Input registers continued