Emerson turbine meter 1500 Manual de Instalação

Consulte online ou descarregue Manual de Instalação para não Emerson turbine meter 1500. Emerson turbine meter 1500 Installation and Operation Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - Series 1500 turbine meter

Installation and operation manualPart Number 3-9008-504, rev. KOctober, 2013DanielTM Series 1500 turbine meter 3" thru 18" sizes

Página 2

OCT 2013 DANIEL™ SERIES 1500 TURBINE METERTABLE OF CONTENTSiiThis page intentionally left blank.

Página 3

DANIEL™ SERIES 1500 TURBINE METER OCT 2013TABLE OF CONTENTS iiiFigures3-1 Typical Installation ... 3-

Página 4

OCT 2013 DANIEL™ SERIES 1500 TURBINE METERTABLE OF CONTENTSivThis page intentionally left blank.

Página 5

DANIEL™ SERIES 1500 TURBINE METER OCT 2013INTRODUCTION 1-11.0 INTRODUCTION1.1 GeneralThis manual is designed to assist in the installation and operati

Página 6

OCT 2013 DANIEL™ SERIES 1500 TURBINE METERINTRODUCTION1-2This page intentionally left blank.

Página 7

DANIEL™ SERIES 1500 TURBINE METER OCT 2013SPECIFICATIONS 2-12.0 SPECIFICATIONSThis meter is designed for use within the guidelines of API Standards, C

Página 8

OCT 2013 DANIEL™ SERIES 1500 TURBINE METERSPECIFICATIONS2-2INMETRO certification Certification numberand markingApplicable norms ABNT NBR IEC 60079-0:

Página 9

DANIEL™ SERIES 1500 TURBINE METER OCT 2013Pressure/Temperature Carbon Steel Stainless SteelSPECIFICATIONS2-3600 ANSI / -20 to 100°F (-29° to 82°C)1480

Página 10 - TABLE OF CONTENTSii

OCT 2013 DANIEL™ SERIES 1500 TURBINE METERSPECIFICATIONS2-4Meter Performance Linearity ± 0.15% (Linearity options of ± 0.1% and ± 0.07% available on c

Página 11 - OCT 2013

DANIEL™ SERIES 1500 TURBINE METER OCT 2013SPECIFICATIONS 2-5Type: Square WaveFrequency Range: 0 to 5 kHzMax. Voltage: 30 VdcMax. Current: 125 mAMax. P

Página 13

OCT 2013 DANIEL™ SERIES 1500 TURBINE METERSPECIFICATIONS2-6This page intentionally left blank.

Página 14

DANIEL™ SERIES 1500 TURBINE METER OCT 2013INSTALLATION 3-13.0 INSTALLATION3.1 GeneralThis section contains specific instructions for installation of t

Página 15

OCT 2013 DANIEL™ SERIES 1500 TURBINE METERINSTALLATION3-23.3 Installation and EquipmentFigure 3-1, Typical Installation, has been provided as a guide

Página 16

DANIEL™ SERIES 1500 TURBINE METER OCT 2013INSTALLATION 3-3When installing this equipment, bolting must conform to the requirements of ASME B16.5paragr

Página 17 - /F (-29/C)

OCT 2013 DANIEL™ SERIES 1500 TURBINE METERINSTALLATION3-4MECHANICAL EQUIPMENT DAMAGEAlways use a flushing medium that is compatible with the metallurg

Página 18

DANIEL™ SERIES 1500 TURBINE METER OCT 2013INSTALLATION 3-5C. Flow Conditioning PlateThe flow conditioning plate is available for all standard Series 1

Página 19

OCT 2013 DANIEL™ SERIES 1500 TURBINE METERINSTALLATION3-63.4 Pickoff Coils And Electrical ConnectionsA. Pickoff CoilsThe Series 1500 Turbine has the c

Página 20 - SPECIFICATIONS2-6

DANIEL™ SERIES 1500 TURBINE METER OCT 2013INSTALLATION 3-7Figure 3-2. UMB Wiring

Página 21

OCT 2013 DANIEL™ SERIES 1500 TURBINE METERINSTALLATION3-8This page intentionally left blank.

Página 22

DANIEL™ SERIES 1500 TURBINE METER OCT 2013OPERATION 4-14.0 OPERATION4.1 GeneralThis section contains the operating procedures for the Series 1500 Turb

Página 23

Safety signal words and symbolsPay special attention to the following signal words, safety alert symbols and statements: Safety alert symbol This is

Página 24

OCT 2013 DANIEL™ SERIES 1500 TURBINE METEROPERATION4-24.3 OperationFlow and pressure information is stamped on the nameplate located on the outside of

Página 25

DANIEL™ SERIES 1500 TURBINE METER OCT 2013MAINTENANCE 5-15.0 MAINTENANCEReference Figures 7-1 through 7-6 Exploded Parts Drawings.Item numbers referen

Página 26

OCT 2013 DANIEL™ SERIES 1500 TURBINE METERMAINTENANCE5-25.3 Disassembly Procedures - Internal ComponentsA. All sizes1. Before removing the meter from

Página 27 - Figure 3-2. UMB Wiring

DANIEL™ SERIES 1500 TURBINE METER OCT 2013MAINTENANCE 5-3Disassembly Step 1Remove the downstream shaft nut,simultaneously holding the upstream shaftnu

Página 28 - INSTALLATION3-8

OCT 2013 DANIEL™ SERIES 1500 TURBINE METERMAINTENANCE5-4Disassembly Step 3Remove downstream cone from the shaft.Thrust washer should remain in cone.Di

Página 29

DANIEL™ SERIES 1500 TURBINE METER OCT 2013MAINTENANCE 5-5Disassembly Step 5Remove journal bearing.Disassembly Step 6Remove upstream cone from the shaf

Página 30 - ªp + 1.25 p

OCT 2013 DANIEL™ SERIES 1500 TURBINE METERMAINTENANCE5-6Disassembly Step 7Remove upstream hanger assembly fromthe opposite end.To do this you must ins

Página 31

DANIEL™ SERIES 1500 TURBINE METER OCT 2013MAINTENANCE 5-75.4 Reassembly of Internal ComponentsIn all cases reassembly is the reverse of disassembly. C

Página 32

OCT 2013 DANIEL™ SERIES 1500 TURBINE METERMAINTENANCE5-85.5 Field Retrofitable Dual PickoffIn the event that a second pickoff is required for equipmen

Página 33

DANIEL™ SERIES 1500 TURBINE METER OCT 2013TROUBLESHOOTING 6-16.0 TROUBLESHOOTING6.1 GeneralThis information has been provided as an aid in basic troub

Página 35

OCT 2013 DANIEL™ SERIES 1500 TURBINE METERTROUBLESHOOTING6-2This page intentionally left blank.

Página 36

DANIEL™ SERIES 1500 TURBINE METER OCT 2013PARTS LIST 7-17.0 PARTS LISTThis section contains the necessary parts required to make up any standard unit

Página 37

OCT 2013 DANIEL™ SERIES 1500 TURBINE METERPARTS LIST7-2Figure 7-1. UMB Assembly - All Sizes (Reference Table 7-1)**Torque 55 in. lbs. (16)

Página 38

DANIEL™ SERIES 1500 TURBINE METER OCT 2013PARTS LIST 7-3Table 7-1. UMB Assembly (All Sizes) (Reference Figure 7-1)ItemNumberDescription Part Number Q

Página 39

OCT 2013 DANIEL™ SERIES 1500 TURBINE METERPARTS LIST7-4Figure 7-2. High Temperature UMB Assembly (Reference Table 7-2)* Torque 55 in. lbs. (26)

Página 40 - TROUBLESHOOTING6-2

DANIEL™ SERIES 1500 TURBINE METER OCT 2013PARTS LIST 7-5Table 7-2. High Temperature UMB Assembly (Reference Figure 7-2)ItemNumberDescription Part Num

Página 41

OCT 2013 DANIEL™ SERIES 1500 TURBINE METERPARTS LIST7-6Figure 7-3. 3" through 18" Uni-Directional 1500 Series Turbine (Reference Table 7-3)

Página 42

DANIEL™ SERIES 1500 TURBINE METER OCT 2013PARTS LIST 7-7Table 7-3. 3" through 8"Uni-Directional Series 1500 Turbine Meter(Reference Figure

Página 43

OCT 2013 DANIEL™ SERIES 1500 TURBINE METERPARTS LIST7-8Figure 7-4. 4" through 8" Bi-Directional Series 1500 Series (Reference Table 7-4)

Página 44

DANIEL™ SERIES 1500 TURBINE METER OCT 2013PARTS LIST 7-9Table 7-4. 4" through 8"Bi-Directional Series 1500 Turbine Meter(Reference Figure 7

Página 45

Important safety instructionsDaniel Measurement and Control, Inc. (Daniel) designs, manufactures and tests products tofunction within specific conditi

Página 46

OCT 2013 DANIEL™ SERIES 1500 TURBINE METERPARTS LIST7-10Figure 7-5. 10" through 12" Uni-Directional Series 1500 Series (Reference Table 7-5

Página 47 - (Reference Figure 7-3)

DANIEL™ SERIES 1500 TURBINE METER OCT 2013PARTS LIST 7-11Table 7-5. 10" through 12"Uni-Directional Series 1500 Turbine Meter(Reference Figu

Página 48 - PARTS LIST7-8

OCT 2013 DANIEL™ SERIES 1500 TURBINE METERPARTS LIST7-12Figure 7-6. 16" through 18" Uni-Directional Series 1500 Series (Reference Table 7-6)

Página 49 - (Reference Figure 7-4)

DANIEL™ SERIES 1500 TURBINE METER OCT 2013PARTS LIST 7-13Table 7-6. 16" through 18"Uni-Directional Series 1500 Turbine Meter(Reference Figu

Página 50 - PARTS LIST7-10

OCT 2013 DANIEL™ SERIES 1500 TURBINE METERPARTS LIST7-14This page intentionally left blank.

Página 51

Daniel Measurement and Control, Inc.Returned Material AuthorizationRepair Form for Used EquipmentIncluding Decontamination/Cleaning StatementA Return

Página 52

Shipping RequirementsFailure to comply with this procedure will result in the shipment being refused.1. Write the RMA number on the shipping package.2

Página 56 - Shipping Requirements

Product operation personnel:• To prevent personal injury, personnel must follow all instructions of this manual prior to andduring operation of the p

Página 57

Emerson Process ManagementDaniel Measurement and Control, Inc.11100 Brittmoore Park DriveHouston, TX 77041T+1 713-467-6000F+1 713-827-4805www.emerson.

Página 58

NoticeTHE CONTENTS OF THIS PUBLICATION ARE PRESENTED FOR INFORMATIONAL PURPOSES ONLY,AND WHILE EVERY EFFORT HAS BEEN MADE TO ENSURE THEIR ACCURACY, TH

Página 59

Warranty and limitation of liability1. LIMITED WARRANTY: Subject to the limitations contained in Section 2 herein, Daniel Measurement & Control,I

Página 60

DANIEL™ SERIES 1500 TURBINE METER OCT 2013TABLE OF CONTENTS iTABLE OF CONTENTS1.0 INTRODUCTION .............. 1-

Comentários a estes Manuais

Sem comentários