Emerson HSP2600 Manual de Instruções Página 6

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 11
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 5
10
11
The Humidier Automatic Flushing Timer
automatically ushes accumulated min-
eral deposits from all central-system
steam- and reservoir-type humidiers.
This enables homeowners to enjoy the
benets of healthful, humidied air without
the hassles of frequent maintenance due
to mineral buildup.
The ushing timer is set at the factory
to ush the humidier every two hours
for a duration of 10 seconds, using
only about 1.5 gallons of water per day.
(See “To Reprogram the Automatic Flushing Timer”, pages 11 and 12, for
alternate settings.) This ushing reduces or eliminates servicing during the
humidication season, depending on the mineral content of the water.
How To Install the
Pro grammable Automatic Flushing Timer
To Install the Flushing Timer on a Steam Humidier:
Locate a suitable waste drain for disposal of ushed water.
CAUTION: Drain tubing must not kink or come in contact with
sharp edges or hot surfaces. Tubing must run in a continual down-
hill slope to allow proper drainage and to prevent overow.
4a. If this ushing timer was purchased as an accessory to install on a
steam humidier... remove the drain valve from the humidier and
install the 90º barbed tting (provided). (See Figure 9 on page 10.)
4b. If this ushing timer was purchased with the steam humidier as a
complete assembly... the 90º barbed tting should already be installed
on the humidier in the proper location. (See Figure 9 on page 10.)
Screw the unit to the mounting surface selected in Step #2.
Cut a piece of drain tubing to reach from the humidier tting to the tting
on the side of the ushing timer.
CAUTION: Drain tubing must not kink or come in contact with sharp
edges or hot surfaces. (This caution applies to step #7, as well.)
Cut a second piece of tubing to reach from the bottom tting on the
ushing timer to the drain. (See Step #3.)
Connect tubing with clamps or ttings suitable for your installation.
Return the steam humidier to its normal operating mode. Refer to pages
8 & 9 to properly set the water level.
Plug the ushing timer into the designated outlet. (See Step #2.)
Check all ttings for leaks. Tighten as necessary.
Test the ushing timer for proper operation.
Press and release the MANUAL button.
Wait 10 to 30 seconds* until the ushing noise stops, indicating that
the ushing cycle is complete.
*The number of seconds will vary depending upon how the unit is
programmed. (See “To Reprogram the Automatic Flushing Timer”,
below.)
To Reprogram the Automatic Flushing Timer:
The ushing timer is set at the factory to ush the humidier every two hours
for a duration of 10 seconds, using approximately 1.5 gallons of water per
day. Although the two-hour intervals between ushes may not be altered, the
duration may be lengthened to either 20 or 30 seconds per ush.
Unplug the ushing timer from the electrical outlet.
Take off the back cover plate by removing the three screws closest to
the mounting anges.
3.
5.
6.
7.
8.
9.
10.
11.
12.
A.
B.
1.
2.
Figure 9—Installation of a
Programmable Automatic
Flushing Timer on a Steam
Humidier
CAUTION: All plumb-
ing and electrical con-
nections must comply
with relevant codes and
ordinances.
If the humidier has
been preinstalled and
needs servicing, refer
to “How to Maintain a
White-Rodgers Com-
fortPlus Humidier”
(page 12) for instructions.
For either a new or preinstalled humidier, select a suitable mounting
locations for the ushing timer within 3 feet of the humidier, and within
10 feet of a properly fused electrical outlet.