Página 1 - AXP 1410

Embedded Computing forBusiness-Critical ContinuityTMAXP 1410Installation and UseP/N: 6806800H70DOctober 2010

Página 2 - Contact Address

AXP 1410 Installation and Use (6806800H70D)10 List of TablesTable 7-21 Sensor No. 16 Fan 3 Outlet . . . . . . . . . . . . . . . . . . . . . . . .

Página 3 - Contents

Configuring and Operating the SystemAXP 1410 Installation and Use (6806800H70D)100Access via base interface channel 2:For further information on the

Página 4

Configuring and Operating the SystemAXP 1410 Installation and Use (6806800H70D)1015.4.2 UpgradeThe procedures and tools for software upgrades differ

Página 5

Configuring and Operating the SystemAXP 1410 Installation and Use (6806800H70D)102Please refer to the Release Notes to find out about software depend

Página 6

Configuring and Operating the SystemAXP 1410 Installation and Use (6806800H70D)103Power conversion for the SAMs and PEMs consists of two 66 watt, +48

Página 7

Configuring and Operating the SystemAXP 1410 Installation and Use (6806800H70D)104voltage sensors to detect backplane voltages, current sensors to de

Página 8

Configuring and Operating the SystemAXP 1410 Installation and Use (6806800H70D)105The FTMs have variable speed fan control, which is dependent on the

Página 9

Configuring and Operating the SystemAXP 1410 Installation and Use (6806800H70D)1065.6.3 IPMC CircuitryPreprogrammed FRU and SDR information reside on

Página 10 - List of Tables

Configuring and Operating the SystemAXP 1410 Installation and Use (6806800H70D)1075.7.1.1 HeartbeatThe shelf managers use two private interfaces to h

Página 11

Configuring and Operating the SystemAXP 1410 Installation and Use (6806800H70D)1085.7.2 System Start-Up Behavior and DependenciesOnce the system is p

Página 12

Configuring and Operating the SystemAXP 1410 Installation and Use (6806800H70D)1095.7.2.2 Hub BladeHub blades are associated with a shelf manager. Hu

Página 13 - List of Figures

List of TablesAXP 1410 Installation and Use (6806800H70D)11Table 8-2 Alarm Display Panel (ADP) Serial Port Connector . . . . . . . . . . . . . . . .

Página 14

Configuring and Operating the SystemAXP 1410 Installation and Use (6806800H70D)110The figure below assumes that the shelf address is 0. Green color s

Página 15 - About this Manual

Configuring and Operating the SystemAXP 1410 Installation and Use (6806800H70D)1115.7.3 Redundancy OperationsThis section describes what happens duri

Página 16 - Abbreviations

Configuring and Operating the SystemAXP 1410 Installation and Use (6806800H70D)112The figure below assumes that the shelf address is 0. Green color s

Página 17

Configuring and Operating the SystemAXP 1410 Installation and Use (6806800H70D)1134. If necessary, moves its own active virtual IP address to another

Página 18

Configuring and Operating the SystemAXP 1410 Installation and Use (6806800H70D)114The system manager performs the following steps:1. Closes the HPI s

Página 19 - Conventions

Configuring and Operating the SystemAXP 1410 Installation and Use (6806800H70D)115The figure below assumes that the shelf address is 0. Green color s

Página 20 - Summary of Changes

Configuring and Operating the SystemAXP 1410 Installation and Use (6806800H70D)116The active shelf manager synchronizes the shelf FRU information wit

Página 21 - Comments and Suggestions

Configuring and Operating the SystemAXP 1410 Installation and Use (6806800H70D)1175.8.1 Power-On After Blade InsertionThe default for each slot is th

Página 22

Configuring and Operating the SystemAXP 1410 Installation and Use (6806800H70D)1185.8.2 Power-Down Before Blade ExtractionWhen a blade is supposed to

Página 23 - System Overview

Chapter 6 AXP 1410 Installation and Use (6806800H70D)119Supported IPMI Commands6.1 IntroductionThis chapter describes the different commands supported

Página 24

AXP 1410 Installation and Use (6806800H70D)12 List of Tables

Página 25

Supported IPMI CommandsAXP 1410 Installation and Use (6806800H70D)1206.2.3 Sensor Device CommandsThe IPMC supports the following sensor device comman

Página 26 - 1.1.3 Shelf Manager

Supported IPMI CommandsAXP 1410 Installation and Use (6806800H70D)1216.3 PICMG 3.0 CommandsThe Emerson IPMC is a fully compliant AdvancedTCA Intellig

Página 27 - 1.1.4 Blades

Supported IPMI CommandsAXP 1410 Installation and Use (6806800H70D)122

Página 28 - 1.1.8 Fan Tray Modules

Chapter 7 AXP 1410 Installation and Use (6806800H70D)123FRU Information and Sensor Data Records7.1 IntroductionThis chapter introduces FRU information

Página 29 - 1.2 Standard Compliances

FRU Information and Sensor Data RecordsAXP 1410 Installation and Use (6806800H70D)12412 Fan 5 Fan Fan Unit 5 Inlet Fan RPM Threshold Always13 Fan 6 F

Página 30 - 1.3 Ordering Information

FRU Information and Sensor Data RecordsAXP 1410 Installation and Use (6806800H70D)1257.2.2 Fan Tray Module Analog SensorsThe analog sensors available

Página 31

FRU Information and Sensor Data RecordsAXP 1410 Installation and Use (6806800H70D)126Entity ID 0x0A Power SupplyEntity Instance 0x60Rearm mode AutoHy

Página 32 - 1.4 Product Identification

FRU Information and Sensor Data RecordsAXP 1410 Installation and Use (6806800H70D)127Readable threshold mask, Settable threshold mask (bytes 19, 20)0

Página 33

FRU Information and Sensor Data RecordsAXP 1410 Installation and Use (6806800H70D)128Table 7-5 Sensor No. 6 +5V A_MONFeature Raw Value/Description In

Página 34

FRU Information and Sensor Data RecordsAXP 1410 Installation and Use (6806800H70D)1297.2.2.2 Temperature SensorsThe following sensors measure tempera

Página 35 - Site Preparation

List of FiguresAXP 1410 Installation and Use (6806800H70D)13Figure 1-1 System Front View . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 36

FRU Information and Sensor Data RecordsAXP 1410 Installation and Use (6806800H70D)130Threshold access support Readable/SettableEvent message control

Página 37 - 2.3 Requirements

FRU Information and Sensor Data RecordsAXP 1410 Installation and Use (6806800H70D)131Table 7-9 Sensor No. 32 FTM Temp 3Feature Raw Value/Description

Página 38

FRU Information and Sensor Data RecordsAXP 1410 Installation and Use (6806800H70D)132Hysteresis support Readable/SettableThreshold access support Rea

Página 39 - 2.3.2 Power Requirements

FRU Information and Sensor Data RecordsAXP 1410 Installation and Use (6806800H70D)1337.2.2.3 Fan Speed SensorsThe following sensors measure the speed

Página 40 - 2.4 Dimensions and Weight

FRU Information and Sensor Data RecordsAXP 1410 Installation and Use (6806800H70D)134Entity ID 0x1D Cooling UnitEntity Instance 0x63Rearm mode AutoHy

Página 41 - 2.5 Mounting Options

FRU Information and Sensor Data RecordsAXP 1410 Installation and Use (6806800H70D)135Readable threshold mask, Settable threshold mask (bytes 19, 20)0

Página 42 - 2.6 Cooling Considerations

FRU Information and Sensor Data RecordsAXP 1410 Installation and Use (6806800H70D)136Table 7-16 Sensor No. 11 Fan 4Feature Raw Value/Description Inte

Página 43

FRU Information and Sensor Data RecordsAXP 1410 Installation and Use (6806800H70D)137Entity Instance 0x63Rearm mode AutoHysteresis support Readable/S

Página 44 - 2.7 Acoustic Noise Control

FRU Information and Sensor Data RecordsAXP 1410 Installation and Use (6806800H70D)138Readable threshold mask, Settable threshold mask (bytes 19, 20)0

Página 45

FRU Information and Sensor Data RecordsAXP 1410 Installation and Use (6806800H70D)139Table 7-20 Sensor No. 15 Fan 2 OutletFeature Raw Value/Descripti

Página 46 - 3.3 Installation

AXP 1410 Installation and Use (6806800H70D)14 List of Figures

Página 47

FRU Information and Sensor Data RecordsAXP 1410 Installation and Use (6806800H70D)140Entity Instance 0x63Rearm mode AutoHysteresis support Readable/S

Página 48

FRU Information and Sensor Data RecordsAXP 1410 Installation and Use (6806800H70D)141Readable threshold mask, Settable threshold mask (bytes 19, 20)0

Página 49

FRU Information and Sensor Data RecordsAXP 1410 Installation and Use (6806800H70D)1427.2.3 Fan Tray Module Discrete SensorsThe following tables descr

Página 50

FRU Information and Sensor Data RecordsAXP 1410 Installation and Use (6806800H70D)1437.2.3.1 Hot Swap SensorThe following table describes the discret

Página 51 - 3.3.2 Connecting the Cables

FRU Information and Sensor Data RecordsAXP 1410 Installation and Use (6806800H70D)1447.2.3.3 Reserved SensorThe following table describes the reserve

Página 52 - 3.3.2.1 DC Power Cable

FRU Information and Sensor Data RecordsAXP 1410 Installation and Use (6806800H70D)1457.2.3.4 OEM-Reserved SensorsThe following table describes the OE

Página 53

FRU Information and Sensor Data RecordsAXP 1410 Installation and Use (6806800H70D)146Assertion Event Mask (bytes 15,16)0x02, 0x00Deassertion Event Ma

Página 54

FRU Information and Sensor Data RecordsAXP 1410 Installation and Use (6806800H70D)147Table 7-30 Sensor No. 22 FanFault Z1F3Feature Raw Value/Descript

Página 55

FRU Information and Sensor Data RecordsAXP 1410 Installation and Use (6806800H70D)148Assertion Event Mask (bytes 15,16)0x02, 0x00Deassertion Event Ma

Página 56 - 3.3.3 Grounding the System

FRU Information and Sensor Data RecordsAXP 1410 Installation and Use (6806800H70D)149Table 7-33 Sensor No. 25 FanFault Z2F3Feature Raw Value/Descript

Página 57 - 3.3.4 Powering Up the System

AXP 1410 Installation and Use (6806800H70D)15 About this ManualOverview of ContentsThis manual is divided into the following chapters and appendix.z C

Página 58 - 3.5 Emergency Power Off

FRU Information and Sensor Data RecordsAXP 1410 Installation and Use (6806800H70D)150Assertion Event Mask (bytes 15,16)0x02, 0x00Deassertion Event Ma

Página 59

FRU Information and Sensor Data RecordsAXP 1410 Installation and Use (6806800H70D)151Table 7-36 Sensor No. 28 FuseFail 48VB1Feature Raw Value/Descrip

Página 60

FRU Information and Sensor Data RecordsAXP 1410 Installation and Use (6806800H70D)1527.3 Power Entry Module Sensor Data RecordsThis section describes

Página 61 - FRU Installation

FRU Information and Sensor Data RecordsAXP 1410 Installation and Use (6806800H70D)153 Board Product Name = Centellis 4000 Power Entry Module

Página 62

FRU Information and Sensor Data RecordsAXP 1410 Installation and Use (6806800H70D)1547.3.3 Power ConfigurationThe next table describes the power conf

Página 63 - 4.2.1 Installing the Board

FRU Information and Sensor Data RecordsAXP 1410 Installation and Use (6806800H70D)1557.3.5 Power Entry Module Analog SensorsThe analog sensors availa

Página 64 - 4.2.2 Removing the Board

FRU Information and Sensor Data RecordsAXP 1410 Installation and Use (6806800H70D)1567.3.5.1 Voltage SensorsThe following sensors measure voltages of

Página 65 - 4.3.2 Removing the PEM

FRU Information and Sensor Data RecordsAXP 1410 Installation and Use (6806800H70D)157Table 7-41 Sensor No. 3 +12V MeasureFeature Raw Value/Descriptio

Página 66

FRU Information and Sensor Data RecordsAXP 1410 Installation and Use (6806800H70D)158Entity Instance 0x60Rearm mode AutoHysteresis support Readable/S

Página 67

FRU Information and Sensor Data RecordsAXP 1410 Installation and Use (6806800H70D)159Readable threshold mask, Settable threshold mask (bytes 19, 20)0

Página 68 - 4.3.3 Installing the PEM

AXP 1410 Installation and Use (6806800H70D)About this Manual16 About this Manual AbbreviationsThis document uses the following abbreviations:Abbreviat

Página 69

FRU Information and Sensor Data RecordsAXP 1410 Installation and Use (6806800H70D)160Table 7-45 Sensor No. 14, 48.0V FEED_2Feature Raw Value/Descript

Página 70

FRU Information and Sensor Data RecordsAXP 1410 Installation and Use (6806800H70D)1617.3.5.2 Current SensorsThe following table describes the sensors

Página 71

FRU Information and Sensor Data RecordsAXP 1410 Installation and Use (6806800H70D)1627.3.5.3 Temperature SensorThe following tables describe the temp

Página 72

FRU Information and Sensor Data RecordsAXP 1410 Installation and Use (6806800H70D)1637.3.6 Power Entry Module Discrete SensorsThe following tables de

Página 73 - 4.4.1 Removing the Upper FTM

FRU Information and Sensor Data RecordsAXP 1410 Installation and Use (6806800H70D)1647.3.6.2 IPMB Link SensorThe following table describes the IPMB l

Página 74 - 4.4.3 Removing the Lower FTM

FRU Information and Sensor Data RecordsAXP 1410 Installation and Use (6806800H70D)1657.3.6.3 Circuit Breaker State SensorsThe following tables descri

Página 75 - 4.5 Installing a Fan Filter

FRU Information and Sensor Data RecordsAXP 1410 Installation and Use (6806800H70D)166Assertion Event Mask (byte 15, 16)0x02, 0x00Deassertion Event Ma

Página 76

FRU Information and Sensor Data RecordsAXP 1410 Installation and Use (6806800H70D)167Table 7-53 Sensor No. 7 CB 3Feature Raw Value/Description Interp

Página 77

FRU Information and Sensor Data RecordsAXP 1410 Installation and Use (6806800H70D)168Entity ID 0x0A Power SupplyEntity Instance 0x60Rearm mode AutoEv

Página 78

FRU Information and Sensor Data RecordsAXP 1410 Installation and Use (6806800H70D)169Assertion Event Mask (bytes 15,16)0x02, 0x00Deassertion Event Ma

Página 79 - 5.2 Network Management

About this ManualAXP 1410 Installation and Use (6806800H70D)17FTM Fan Tray ModuleFUMI Firmware Update Management InstrumentGA General AvailabilityGPI

Página 80

FRU Information and Sensor Data RecordsAXP 1410 Installation and Use (6806800H70D)170

Página 81

Chapter 8 AXP 1410 Installation and Use (6806800H70D)171Shelf Management Alarm Module8.1 OverviewThis chapter describes the AdvancedTCA Shelf Manageme

Página 82 - Blade #n

Shelf Management Alarm ModuleAXP 1410 Installation and Use (6806800H70D)172z Support for the Command Line Interface (CLI) to access shelf information

Página 83

Shelf Management Alarm ModuleAXP 1410 Installation and Use (6806800H70D)173interfaces for hardware redundancy, hot swap and carrier ID, plus the ATCA

Página 84

Shelf Management Alarm ModuleAXP 1410 Installation and Use (6806800H70D)1748.3 SAM Diagram and Face Plate Layout Figure 8-1 shows a block diagram of

Página 85 - # hpishaddr -b "07"

Shelf Management Alarm ModuleAXP 1410 Installation and Use (6806800H70D)175The SAM has these interfaces:z Four 10/100Base-T Ethernet links— One link

Página 86 - 5.2.4 IP Addresses

Shelf Management Alarm ModuleAXP 1410 Installation and Use (6806800H70D)1768.4 Functional DescriptionThe SAM has a high-density 220 pin socket for th

Página 87 - SAM1410-2

Shelf Management Alarm ModuleAXP 1410 Installation and Use (6806800H70D)1778.4.3 Master-Only I2C BusThe SAM provides a number of I2C devices using th

Página 88 - 5.2.4.1 Out-of-Band Interface

Shelf Management Alarm ModuleAXP 1410 Installation and Use (6806800H70D)1788.4.5 SAM LEDsThe SAM provides the LEDs listed in the following table. Mor

Página 89

Shelf Management Alarm ModuleAXP 1410 Installation and Use (6806800H70D)1798.4.5.2 SAM/ADP Status LEDsStatus is shown using an LED on the SAM face pl

Página 90

AXP 1410 Installation and Use (6806800H70D)About this Manual18 About this Manual PN Part NumberRFI Radio Frequency InterferenceRFS Root File SystemRMC

Página 91 - 5.2.4.2 Backplane Interfaces

Shelf Management Alarm ModuleAXP 1410 Installation and Use (6806800H70D)1808.5.1.1 Voltage SensorsOn-board sensors provide the following power supply

Página 92

Shelf Management Alarm ModuleAXP 1410 Installation and Use (6806800H70D)181The deltaT set point is calculated as follows:For ambient air temperatures

Página 93

Shelf Management Alarm ModuleAXP 1410 Installation and Use (6806800H70D)182Using the above algorithm, at 40°C ambient, the cooling algorithm adjusts

Página 94 - 5.2.4.3 Configuration File

Shelf Management Alarm ModuleAXP 1410 Installation and Use (6806800H70D)1838.5.2 Redundancy ControlThe ShMM-1500R supports redundant operation with a

Página 95

Shelf Management Alarm ModuleAXP 1410 Installation and Use (6806800H70D)184to the power or ground rails. Hence, the device prevents an unpowered ShMM

Página 96

Shelf Management Alarm ModuleAXP 1410 Installation and Use (6806800H70D)1858.5.2.3 Ethernet SignalsThe SAMs implement a four-port 10/100Base-T Ethern

Página 97

Shelf Management Alarm ModuleAXP 1410 Installation and Use (6806800H70D)1868.5.3 Switchover SignalsA switchover takes place when the Standby SAM dete

Página 98

Shelf Management Alarm ModuleAXP 1410 Installation and Use (6806800H70D)1878.6.1 Telco Alarm Cutoff Push ButtonThe SAM provides a Telco alarm cutoff

Página 99

Shelf Management Alarm ModuleAXP 1410 Installation and Use (6806800H70D)1888.7 Hot Swap InterfaceThe SAM provides a hot swap interface allowing the S

Página 100 - 5.4 Software

Shelf Management Alarm ModuleAXP 1410 Installation and Use (6806800H70D)1898.9.1 imls UtilityA utility called imls is available on the SAM. It can be

Página 101 - 5.4.2 Upgrade

About this ManualAXP 1410 Installation and Use (6806800H70D)19ConventionsThe following table describes the conventions used throughout this manual. N

Página 102 - 5.5 Power Entry Module (PEM)

Shelf Management Alarm ModuleAXP 1410 Installation and Use (6806800H70D)190/dev/mtdblock4:Image Name: shelfman 4.0.0 build 21Created: Fri Jun

Página 103 - 5.5.2 IPMC Circuitry

Appendix AAXP 1410 Installation and Use (6806800H70D)191ARelated DocumentationA.1 Emerson Embedded Communications Computing DocumentsThe Emerson Net

Página 104 - 5.6 Fan Tray Modules

Related DocumentationAXP 1410 Installation and Use (6806800H70D)192A.2 Related SpecificationsFor additional information, refer to the following table

Página 105 - 5.6.2 Cooling Budget

AXP 1410 Installation and Use (6806800H70D)193Safety NotesThis section provides warnings that precede potentially dangerous procedures throughout th

Página 106 - 5.7 Redundancy

AXP 1410 Installation and Use (6806800H70D)Safety Notes194Before you begin to set up and cable your new system, consider these guidelines:z Restricte

Página 107 - 5.7.1.3 HPI Interface

Safety NotesAXP 1410 Installation and Use (6806800H70D)195 Personal Injury or System DamageA top-heavy rack can tip, causing damage to equipment and

Página 108 - 5.7.2.1 Shelf Manager

AXP 1410 Installation and Use (6806800H70D)Safety Notes196 System Damage or Injury Covers and PanelsFailure to operate the system without covering v

Página 109 - 5.7.2.3 System Manager

Safety NotesAXP 1410 Installation and Use (6806800H70D)197 System MalfunctionPrior to the PEM exchange the operating voltage conditions of the system

Página 110 - Figure 5-5 System Start-Up

AXP 1410 Installation and Use (6806800H70D)Safety Notes198 Serious Injury or DeathThis product operates with dangerous voltages that can cause injur

Página 111 - 5.7.3 Redundancy Operations

Safety NotesAXP 1410 Installation and Use (6806800H70D)199 French translation: Cet appareil est conçu pour permettre le raccordement du conducteur r

Página 112

© 2009 Emerson All rights reserved.TrademarksEmerson, Business-Critical Continuity, Emerson Network Power and the Emerson Network Power logo are tra

Página 113

AXP 1410 Installation and Use (6806800H70D)About this Manual20 About this Manual Summary of ChangesThis manual has been revised and replaces all prior

Página 114

AXP 1410 Installation and Use (6806800H70D)Safety Notes200 Personal InjuryCables that are not installed securely can cause injuries due to entangleme

Página 115

Safety NotesAXP 1410 Installation and Use (6806800H70D)201 System Damage MunichRunning the system longer than 30 seconds with less than three f

Página 116

AXP 1410 Installation and Use (6806800H70D)Safety Notes202Couper l’alimentation avant l’entretien et le depannage.For important grounding information

Página 117

Safety NotesAXP 1410 Installation and Use (6806800H70D)203Laser Personal InjuryIf a label with the words CLASS 1 LASER PRODUCT is affixed to the back

Página 118

AXP 1410 Installation and Use (6806800H70D)Safety Notes204VCCI This is a Class A product based on the standard of the Voluntary Control Council for

Página 119 - Supported IPMI Commands

AXP 1410 Installation and Use (6806800H70D)205SicherheitshinweiseDieses Kapitel enthält Hinweise, die potentiell gefährlichen Prozeduren innerhalb d

Página 120 - 6.2.4 FRU Device Commands

AXP 1410 Installation and Use (6806800H70D)Sicherheitshinweise206System Installation Beschädigung des SystemsBitte beachten Sie, dass die im Handbuc

Página 121 - 6.3 PICMG 3.0 Commands

SicherheitshinweiseAXP 1410 Installation and Use (6806800H70D)207 Beschädigung des SystemsDie Gleichspannungseingänge des Systems dürfen ausschließl

Página 122

AXP 1410 Installation and Use (6806800H70D)Sicherheitshinweise208Betrieb Überhitzung des SystemsLüftungsöffnungenUnzureichende Lüftung kann Schäden a

Página 123 - 7.1 Introduction

SicherheitshinweiseAXP 1410 Installation and Use (6806800H70D)209Verunreinigungen in der Luft können den Luftfilter verschmutzen und so die Luftzufuh

Página 124

About this ManualAXP 1410 Installation and Use (6806800H70D)21Comments and SuggestionsWe welcome and appreciate your comments on our documentation. W

Página 125 - 7.2.2.1 Voltage Sensors

AXP 1410 Installation and Use (6806800H70D)Sicherheitshinweise210Falls die ORing Dioden des Produktes durchbrennen, kann das Produkt einen Kurzschlus

Página 126

SicherheitshinweiseAXP 1410 Installation and Use (6806800H70D)211Stecker und Verkabelung Beschädigung des SystemsBei den RJ-45 Steckern, die sich au

Página 127 - Table 7-4 Sensor No. 5 +3.3V

AXP 1410 Installation and Use (6806800H70D)Sicherheitshinweise212 VerletzungsgefahrSchließen Sie in jedem Fall aus, dass Personen durch einen elektri

Página 128

SicherheitshinweiseAXP 1410 Installation and Use (6806800H70D)213 Beschädigung des SystemsEin beschädigter Filter kann Schwebstoffe nur ungenügend a

Página 129 - 7.2.2.2 Temperature Sensors

AXP 1410 Installation and Use (6806800H70D)Sicherheitshinweise214 VerletzungsgefahrStellen Sie sicher, dass das System abgeschaltet und von allen Str

Página 130

SicherheitshinweiseAXP 1410 Installation and Use (6806800H70D)215Laser VerletzungsgefahrWenn sich an der Rückseite Ihres Systems ein Aufkleber mit de

Página 131

AXP 1410 Installation and Use (6806800H70D)Sicherheitshinweise216Änderungen, die nicht ausdrücklich von Emerson erlaubt sind, können Ihr Recht das Sy

Página 132

AXP 1410 Installation and Use (6806800H70D)217Aairflow 105architecture, SAM1500 174ATCA-F120 28BBackplane 26backplane interfaceIP addresses 91baud ra

Página 133 - 7.2.2.3 Fan Speed Sensors

IndexAXP 1410 Installation and Use (6806800H70D)218I2C devices 177Installation 49System 49interfaceshot swap 188serial 176IP address 86backplane inte

Página 134 - Table 7-14 Sensor No. 9 Fan 2

IndexAXP 1410 Installation and Use (6806800H70D)219voltage 180serial interface, SAM 176shelf description 26shelf geographical address 84, 99shelf man

Página 135

AXP 1410 Installation and Use (6806800H70D)About this Manual22 About this Manual

Página 136

IndexAXP 1410 Installation and Use (6806800H70D)220

Página 138

HOW TO REACH LITERATURE AND TECHNICAL SUPPORT:Tempe, Arizona, USA1 800 759 11071 602 438 5720Munich, Germany+49 89 9608 0For literature, training, and

Página 139

Chapter 1 AXP 1410 Installation and Use (6806800H70D)23System Overview1.1 DescriptionThe AXP 1410 system is a high availability AdvancedTCA (Advanced

Página 140

System OverviewAXP 1410 Installation and Use (6806800H70D)24z Air filterz ESD wrist strap sockets and grounding studsFigure 1-1 System Front View CRT

Página 141

System OverviewAXP 1410 Installation and Use (6806800H70D)25Figure 1-2 System Rear View

Página 142

System OverviewAXP 1410 Installation and Use (6806800H70D)261.1.1 ShelfThe AXP 1410 shelf consists of a formed 13U sheet metal card cage with structu

Página 143 - 7.2.3.2 IPMB Link Sensor

System OverviewAXP 1410 Installation and Use (6806800H70D)27For a detailed description refer to the SAM1410 Installation and Use and the System Manag

Página 144 - 7.2.3.3 Reserved Sensor

System OverviewAXP 1410 Installation and Use (6806800H70D)281.1.5 Hub SlotsThe hub slots are configured as option 9 dual star PICMG 3.0 base interfac

Página 145 - 7.2.3.4 OEM-Reserved Sensors

System OverviewAXP 1410 Installation and Use (6806800H70D)291.1.9 Fan FilterThe fan filter is installed in the lower fan tray.1.2 Standard Compliance

Página 146

ContentsAXP 1410 Installation and Use (6806800H70D)3About this Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 147

System OverviewAXP 1410 Installation and Use (6806800H70D)30WEEE ComplianceTo satisfy the requirements for marking electrical and electronic equipmen

Página 148

System OverviewAXP 1410 Installation and Use (6806800H70D)31As of the printing date of this manual, the AXP 1410 Installation and Use supports the sy

Página 149

System OverviewAXP 1410 Installation and Use (6806800H70D)321.4 Product IdentificationYou can find the system label at the back of the system on the

Página 150

System OverviewAXP 1410 Installation and Use (6806800H70D)33The following figure shows a sample label. The actual label on your product may vary in c

Página 151

System OverviewAXP 1410 Installation and Use (6806800H70D)34 The label with the serial number is located at the back of the system on the right.The f

Página 152 - 7.3.1 PEM FRU Information

Chapter 2 AXP 1410 Installation and Use (6806800H70D)35Site Preparation2.1 OverviewThe following sections help you to prepare system installation:2.2

Página 153 - 7.3.2 E-Keying

Site PreparationAXP 1410 Installation and Use (6806800H70D)363. Check the rails for proper alignment.4. Check that the air filter is properly install

Página 154 - 7.3.3 Power Configuration

Site PreparationAXP 1410 Installation and Use (6806800H70D)372.3 RequirementsBefore and during system installation and operation, you always have to

Página 155 - Temperature Sensor

Site PreparationAXP 1410 Installation and Use (6806800H70D)38Shock Half-sine, 11 ms, 30 m/s2 Blade level packagingHalf-sine, 6ms at 180m/s2Vibration

Página 156 - 7.3.5.1 Voltage Sensors

Site PreparationAXP 1410 Installation and Use (6806800H70D)392.3.2 Power RequirementsMake sure that a suitable -40.0 to -72 VDC power source is withi

Página 157

AXP 1410 Installation and Use (6806800H70D)Contents4 Contents Contents3.2.2 Tools You will Need . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 158

Site PreparationAXP 1410 Installation and Use (6806800H70D)402.4 Dimensions and WeightThe table below lists the dimensions and weight of the shelf an

Página 159

Site PreparationAXP 1410 Installation and Use (6806800H70D)412.5 Mounting OptionsYou can simply operate the system on your desk or you can install it

Página 160

Site PreparationAXP 1410 Installation and Use (6806800H70D)42You have to keep the following conditions when installing the system into a 600 mm (23.6

Página 161 - 7.3.5.2 Current Sensors

Site PreparationAXP 1410 Installation and Use (6806800H70D)43Fan trays are mounted in the shelf top. The figure below shows the general airflow for t

Página 162 - 7.3.5.3 Temperature Sensor

Site PreparationAXP 1410 Installation and Use (6806800H70D)442.7 Acoustic Noise ControlThe system can generate a lot of acoustic noise. This system h

Página 163 - 7.3.6.1 Hot Swap Sensor

Chapter 3 AXP 1410 Installation and Use (6806800H70D)45System Installation3.1 OverviewThe following sections help you to start up and maintain the sys

Página 164 - 7.3.6.2 IPMB Link Sensor

System InstallationAXP 1410 Installation and Use (6806800H70D)463.2.2 Tools You will NeedBefore you start the installation, make sure that you have a

Página 165 - Table 7-51 Sensor No. 5, CB 1

System InstallationAXP 1410 Installation and Use (6806800H70D)47Observe the following general safety notes when installing your system:z Restricted a

Página 166 - Table 7-52 Sensor No. 6 CB 2

System InstallationAXP 1410 Installation and Use (6806800H70D)483.3.1 Installing the System in a RackThe following procedure describes how to install

Página 167 - Table 7-54 Sensor No. 8 CB 4

System InstallationAXP 1410 Installation and Use (6806800H70D)49Installation in a 19" RackTo install a system in a 19" rack, proceed as fol

Página 168 - Table 7-55 Sensor No. 9 CB 5

ContentsAXP 1410 Installation and Use (6806800H70D)55.2.3.1 Setting the Shelf Geographical Address . . . . . . . . . . . . . . . . . . . . . . . . .

Página 169

System InstallationAXP 1410 Installation and Use (6806800H70D)50You have to keep the following conditions when installing the system into an at least

Página 170

System InstallationAXP 1410 Installation and Use (6806800H70D)513. Be sure to mount the shelf with metal screws or bolts that give a good electrical

Página 171 - Shelf Management Alarm Module

System InstallationAXP 1410 Installation and Use (6806800H70D)523.3.2.1 DC Power CablePower is introduced to the shelf via redundant DC PEMs. The rec

Página 172 - 8.2 Features

System InstallationAXP 1410 Installation and Use (6806800H70D)53Figure 3-2 DC Power Connection DetailOFFONOFFON-48 VDC RTN -48 VDC VDC

Página 173

System InstallationAXP 1410 Installation and Use (6806800H70D)543.3.2.2 Power Cable TerminationCustom lugs are used with large gauge wires for up to

Página 174

System InstallationAXP 1410 Installation and Use (6806800H70D)55ProcedureHave the following tools on hand before you begin these steps: standard Phil

Página 175

System InstallationAXP 1410 Installation and Use (6806800H70D)569. Break the tagout or lockout seals on the branch circuit or power distribution unit

Página 176 - 8.4 Functional Description

System InstallationAXP 1410 Installation and Use (6806800H70D)57The AXP 1410 shelf was tested in the default configuration of logic ground and shelf

Página 177 - 8.4.4 Shelf FRU SEEPROM

System InstallationAXP 1410 Installation and Use (6806800H70D)583.4 Powering Down the SystemProcedureFollow these steps to shut down your AXP 1410.1.

Página 178 - 8.4.5 SAM LEDs

System InstallationAXP 1410 Installation and Use (6806800H70D)591. Turn each circuit breaker on the front of PEM A and PEM B to the OFF position.2. D

Página 179 - 8.5 Management and Control

AXP 1410 Installation and Use (6806800H70D)Contents6 Contents Contents6 Supported IPMI Commands. . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 180 - 8.5.1.3 Fan Speed and Control

System InstallationAXP 1410 Installation and Use (6806800H70D)60

Página 181

Chapter 4 AXP 1410 Installation and Use (6806800H70D)61FRU Installation4.1 Installing and Removing Node Blades and RTMsRefer to the respective blade o

Página 182

FRU InstallationAXP 1410 Installation and Use (6806800H70D)624.2 Installing and Removing the Shelf Manager BoardThe following figure shows the SAM141

Página 183 - 8.5.2 Redundancy Control

FRU InstallationAXP 1410 Installation and Use (6806800H70D)634.2.1 Installing the BoardTo install the board into an AdvancedTCA shelf, proceed as fol

Página 184 - 8.5.2.2 HRI Protocol

FRU InstallationAXP 1410 Installation and Use (6806800H70D)644.2.2 Removing the BoardThis section describes how to remove the board from an AdvancedT

Página 185 - 8.5.2.3 Ethernet Signals

FRU InstallationAXP 1410 Installation and Use (6806800H70D)654.3 Replacing Power Entry ModulesThe AXP 1410 supports two Power Entry Modules (PEMs). S

Página 186 - 8.6 Telco Alarm Functionality

FRU InstallationAXP 1410 Installation and Use (6806800H70D)66Replacing one PEM is done while the other PEM is in operation. Having the PEM located in

Página 187 - 8.6.3 Telco Alarm Interface

FRU InstallationAXP 1410 Installation and Use (6806800H70D)673. Using the appropriate tool, loosen the chassis retention screws on each side of the P

Página 188 - 8.9 SAM Software

FRU InstallationAXP 1410 Installation and Use (6806800H70D)6810.Remove the DC power cable from the dual lug bolts on the PEM you are replacing, being

Página 189 - 8.9.1 imls Utility

FRU InstallationAXP 1410 Installation and Use (6806800H70D)69Installation ProcedureTo install a PEM, proceed as follows:1. Screw a standoff/lockout s

Página 190

ContentsAXP 1410 Installation and Use (6806800H70D)78 Shelf Management Alarm Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 191 - Related Documentation

FRU InstallationAXP 1410 Installation and Use (6806800H70D)703. Align the threaded end of the standoff/lockout screw extension with the screw holes o

Página 192 - A.2 Related Specifications

FRU InstallationAXP 1410 Installation and Use (6806800H70D)717. Attach the DC power cable to the dual lug bolts on the PEM (power -48VDC input and Re

Página 193 - Safety Notes

FRU InstallationAXP 1410 Installation and Use (6806800H70D)724.4 Installing Fan Tray ModulesTo prevent system damage, the operator must replace the f

Página 194

FRU InstallationAXP 1410 Installation and Use (6806800H70D)734.4.1 Removing the Upper FTMRemoval ProcedureFollow these steps and refer to the figures

Página 195 - Operation

FRU InstallationAXP 1410 Installation and Use (6806800H70D)744.4.2 Installing the Upper FTMInstallation ProcedureHave the correct FTM available and f

Página 196

FRU InstallationAXP 1410 Installation and Use (6806800H70D)753. Open the ejector handle to a full open position.4. Using the ejector handle on the fr

Página 197 - Grounding

FRU InstallationAXP 1410 Installation and Use (6806800H70D)76Replacement ProcedureTo replace the fan filter for a lower FTM, refer to Removing the Lo

Página 198

FRU InstallationAXP 1410 Installation and Use (6806800H70D)775. Lower the vane assembly and rotate the filter bracket into place.6. Reinstall the low

Página 199 - Connectors and Cabling

FRU InstallationAXP 1410 Installation and Use (6806800H70D)78

Página 200 - Expansion and FRU Exchange

Chapter 5 AXP 1410 Installation and Use (6806800H70D)79Configuring and Operating the System5.1 OverviewThe following sections provide information that

Página 201

AXP 1410 Installation and Use (6806800H70D)Contents8 Contents ContentsSafety Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 202

Configuring and Operating the SystemAXP 1410 Installation and Use (6806800H70D)805.2.1 Default VLAN ConfigurationThe AXP 1410 system provides four ne

Página 203 - Environment

Configuring and Operating the SystemAXP 1410 Installation and Use (6806800H70D)81Figure 5-2 Switch Management Base Interface Bridge Configuration

Página 204

Configuring and Operating the SystemAXP 1410 Installation and Use (6806800H70D)825.2.2 Slot Numbers and Slot AddressesThe system provides a dual star

Página 205 - Sicherheitshinweise

Configuring and Operating the SystemAXP 1410 Installation and Use (6806800H70D)83The physical address describes the physical location of an FRU in th

Página 206 - System Installation

Configuring and Operating the SystemAXP 1410 Installation and Use (6806800H70D)845.2.3 Shelf Geographical AddressThe shelf geographical address (SGA)

Página 207

Configuring and Operating the SystemAXP 1410 Installation and Use (6806800H70D)85Example: Changing the shelf geographical address to 7: # hpishaddr -

Página 208

Configuring and Operating the SystemAXP 1410 Installation and Use (6806800H70D)865.2.4 IP AddressesThe following subsections describe the IP addresse

Página 209

Configuring and Operating the SystemAXP 1410 Installation and Use (6806800H70D)87The figure below shows an example of the shelf manager IP addresses

Página 210

Configuring and Operating the SystemAXP 1410 Installation and Use (6806800H70D)88Abbreviations used are as follows:5.2.4.1 Out-of-Band InterfaceThe I

Página 211 - Stecker und Verkabelung

Configuring and Operating the SystemAXP 1410 Installation and Use (6806800H70D)89Virtual Standby IP Address on Out-of-Band InterfaceTo avoid an addre

Página 212

List of TablesAXP 1410 Installation and Use (6806800H70D)9Table 1-1 Standard Compliances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 213

Configuring and Operating the SystemAXP 1410 Installation and Use (6806800H70D)90Example #1: Print current IP address settings and change out-of-band

Página 214

Configuring and Operating the SystemAXP 1410 Installation and Use (6806800H70D)91*change Shelf Address and Shelf Entity Path setting:shm9s8:~ # hpish

Página 215 - Umweltschutz

Configuring and Operating the SystemAXP 1410 Installation and Use (6806800H70D)92Physical IP Address on Backplane Interface 2The following virtual IP

Página 216

Configuring and Operating the SystemAXP 1410 Installation and Use (6806800H70D)93Refer to Setting the Shelf Geographical Address on page 84 to see ho

Página 217

Configuring and Operating the SystemAXP 1410 Installation and Use (6806800H70D)94shm9s8:~ # hpiship -n 8449 -i 200.200.0.05.2.4.3 Configuration FileB

Página 218

Configuring and Operating the SystemAXP 1410 Installation and Use (6806800H70D)95auto - Automatic configuration of the interfacedhcp - Use DHCP t

Página 219 - , 180, 188

Configuring and Operating the SystemAXP 1410 Installation and Use (6806800H70D)96The backplane virtual application interface can be configured automa

Página 220

Configuring and Operating the SystemAXP 1410 Installation and Use (6806800H70D)97BP_B_DHCP_SERVER=z Backplane Bonding ModeThe backplane interfaces ca

Página 221

Configuring and Operating the SystemAXP 1410 Installation and Use (6806800H70D)98GATEWAY=z Heartbeat AddressesThe ppp0 and ppp1 serial links are used

Página 222 - © 2009 Emerson Electric Co

Configuring and Operating the SystemAXP 1410 Installation and Use (6806800H70D)995.3 Accessing System ComponentsAll system components are delivered w