Emerson 1410 Manual de Serviço Página 111

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 222
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 110
Configuring and Operating the System
AXP 1410 Installation and Use (6806800H70D)
111
5.7.3 Redundancy Operations
This section describes what happens during shelf manager switchover, takeover, failover, and
when a shelf manager is inserted or extracted.
5.7.3.1 Shelf Manager Switchover
During a switchover, the active and the standby shelf manager change their roles. The system
manager initiates and controls this process on the active shelf manager. A switchover is, for
example, necessary when the active shelf manager needs to be extracted. Since only the
standby shelf manager can be extracted, a switchover needs to take place.
Vista de página 110
1 2 ... 106 107 108 109 110 111 112 113 114 115 116 ... 221 222

Comentários a estes Manuais

Sem comentários