www.Fisher.com
Fisherr FIELDVUE
DLC3010 Digital Level
Controller
Contents
Installation 3.....................
Mounting 9.......................
Electrical Connections 13...........
Initial Setup 21....................
Calibration 27.....................
Schematics 32....................
Specifications 34..................
Note
This guide describes how to install, setup, and calibrate DLC3010 digital level controllers using a 475 Field Communicator.
Additional information for installing, operating, and maintaining the DLC3010 digital level controllers can be found in the related
documents listed on page 42. For information on using the Field Communicator, see the Product Manual
for the Field
Communicator, available from Emerson Performance Technologies.
Quick Start Guide
D103214X012
DLC3010 Digital Level Controller
September 2014
This quick start guide applies to:
Device Type 3010
Device Revision 1
Hardware Revision 1
Firmware Revision 8
DD Revision 3
W7977-1
Vista de página 0
1 2 3 4 5 6 ... 43 44

Resumo do Conteúdo

Página 1 - Controller

www.Fisher.comFisherr FIELDVUE™ DLC3010 Digital LevelControllerContentsInstallation 3...Mounting 9...Electrical

Página 2 - Mounting

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201410DLC3010 OrientationMount the digital level controller with the torque tube

Página 3 - Installation

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201411Figure 5. Typical Mounting Positions for FIELDVUE DLC3010 Digital Level Co

Página 4

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201412Mounting the Digital Level Controller for Extreme TemperatureApplicationsR

Página 5 - Lever Lock

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 2014131. For mounting a digital level controller on a 249 sensor, secure the sh

Página 6 - WARNING

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201414Figure 9. Connecting a Field Communicator to the Digital Level Controller

Página 7

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201415Field Wiring WARNINGTo avoid personal injury or property damage caused

Página 8

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201416Grounding WARNINGPersonal injury or property damage can result from fir

Página 9

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201417Communication Connections WARNINGPersonal injury or property damage cause

Página 10 - DLC3010 Orientation

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201418the instrument drives its output to either below 3.70 mA or above 22.5 mA,

Página 11 - Quick Start Guide

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201419Loop Test (optional)Field Communicator Service Tools > Maintenance >

Página 12 - Applications

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 20142nInstallation Check ListInstrument correctly configured and mounted on the

Página 13 - Electrical Connections

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201420nConfiguration and Calibration Check ListInitial setup complete. Perform t

Página 14

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201421Configuration and Calibration Initial SetupIf a DLC3010 digital level cont

Página 15 - Field Wiring

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201422D Instrument mounting (right or left of displacer)D Measurement Applicatio

Página 16 - Grounding

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201423Figure 12. Example Sensor NameplateDISPLACERPRESSURE RATING1500 PSI103 CU‐

Página 17 - Alarm Jumper

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201424HORIZONTAL CLOF TORQUE TUBEVERTICAL CL OF DISPLACERMOMENTARM LENGTHVESSELF

Página 18 - Changing Jumper Position

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 2014258. The default values of the alarm variables will be set as follows:Direc

Página 19 - Loop Test (optional)

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201426Coupling If the digital level controller is not already coupled to the se

Página 20 - September 2014

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201427CalibrationGuided CalibrationField Communicator Configure > Calibration

Página 21 - Initial Setup

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201428until sufficient buoyancy has developed to allow the linkage to move. In t

Página 22 - Guided Setup

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201429The calibration process flows as follows:D Change the PV mode to Level.D S

Página 23

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 20143Installation WARNINGTo avoid personal injury, always wear protective glov

Página 24

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201430Density Applications - with Standard Displacer and Torque TubeNoteWhen you

Página 25

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 2014311. Determine all the information you can about the 249 hardware: 249 type

Página 26 - Coupling

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201432SchematicsThis section includes loop schematics required for wiring of int

Página 27 - Calibration

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201433Figure 15. FM Loop Schematic28B5745‐C1. THE INSTALLATION MUST BE IN ACCOR

Página 28

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201434SpecificationsSpecifications for DLC3010 digital level controllers are sho

Página 29

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201435Table 6. DLC3010 Digital Level Controller SpecificationsAvailable Configur

Página 30

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201436Table 6. DLC3010 Digital Level Controller Specifications (continued)Electr

Página 31

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201437Table 6. DLC3010 Digital Level Controller Specifications (continued)Minimu

Página 32 - Schematics

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201438Table 7. EMC Summary Results—ImmunityPort Phenomenon Basic Standard Test L

Página 33

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201439Figure 16. Theoretical Reversible Temperature Effect on Common Torque Tube

Página 34 - Specifications

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 20144Figure 1. Installation FlowchartSTART HEREFactory mountedon 249 sensor?Use

Página 35 - J reverse action—increasing

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201440Table 8. 249 Sensor SpecificationsInput SignalLiquid Level or Liquid‐to‐Li

Página 36

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201441Table 11. Caged Displacer Sensors(1)TORQUE TUBEORIENTATIONSENSORSTANDARD C

Página 37 - J Mountings for Masoneilant

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201442Figure 17. Style Number of Equalizing ConnectionsSTYLE 1TOP AND BOTTOM CON

Página 38

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201443D Bolt Torque Information - Supplement to 249 Sensor Instruction Manuals (

Página 39

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 201444Emerson Process Management Marshalltown, Iowa 50158 USASorocaba, 18087 Bra

Página 40 - J Reflex gauges for

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 20145Configuration: On the Bench or in the LoopConfigure the digital level contr

Página 41

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 20146CAUTIONWhen shipping an instrument mounted on a sensor, if the lever assemb

Página 42 - Related Documents

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 20147Table 1. Hazardous Area Classifications—CSA (Canada)Certification Body Cert

Página 43 - Educational Services

Quick Start GuideD103214X012DLC3010 Digital Level ControllerSeptember 20148Type nThis equipment shall be used with a cable entry ensuring an IP66 mini