Emerson Rosemount 3300 Series Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Medição, teste e controlo Emerson Rosemount 3300 Series. Product Data Sheet [en] Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 38
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
Product Data Sheet
00813-0100-4811, Rev DA
Catalog 2008 - 2009
Rosemount 3300 Series
www.rosemount.com
The Rosemount 3300 Series is a smart, loop-
powered level and interface transmitter, based on
guided wave radar technology. The instrument
provides reliable measurements on liquids and
slurries, even for severe conditions, due to advanced
signal processing with digital sampling and a high
signal to noise ratio.
Easy installation and commissioning through
two-wire technology, and pre-configured
transmitter or user-friendly configuration with
included PC software package.
Trouble-free operation since the transmitter is
virtually unaffected by dust,vapor, interfering
obstacles, and turbulence. It is even suitable
for small or oddly shaped tanks.
Direct level measurement means no
compensation for changes in temperature,
pressure, density, dielectric, or conductivity.
Robust modular design with dual
compartment housing, which can be removed
without opening the tank.
High application flexibility with a wide range of
probe styles in different materials and options
to handle corrosive media, extreme
temperature and pressure.
Multivariable™ level and interface transmitter
reduces process penetrations and installation
costs.
Content
Measurement Principle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Level-2
Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Level-2
System Integration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Level-4
Select Guided Wave Radar Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Level-6
Measuring Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Level-10
Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Level-11
Replacing a Displacer in an Existing Displacer Cage . . . . . . . . . . . . . . . . . . . . . . Level-12
Mechanical Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Level-13
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Level-14
Product Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Level-17
Dimensional Drawings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Level-19
Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Level-28
Guided Wave Radar Level and Interface
Transmitter
Vista de página 0
1 2 3 4 5 6 ... 37 38

Resumo do Conteúdo

Página 1 - Transmitter

Product Data Sheet00813-0100-4811, Rev DACatalog 2008 - 2009Rosemount 3300 Serieswww.rosemount.comThe Rosemount 3300 Series is a smart, loop- powered

Página 2 - Measurement Principle

Product Data Sheet00813-0100-4811, Rev DACatalog 2008 - 2009Rosemount 3300 SeriesLevel-10Measuring RangeIn the table below, measuring range informatio

Página 3

Product Data Sheet00813-0100-4811, Rev DACatalog 2008 - 2009Level-11Rosemount 3300 SeriesInterfaceRosemount 3302 is the ideal choice for measuring the

Página 4 - System Integration

Product Data Sheet00813-0100-4811, Rev DACatalog 2008 - 2009Rosemount 3300 SeriesLevel-12Replacing a Displacer in an Existing Displacer CageA Rosemoun

Página 5

Product Data Sheet00813-0100-4811, Rev DACatalog 2008 - 2009Level-13Rosemount 3300 SeriesMechanical ConsiderationsTypically the transmitter is top mou

Página 6

Product Data Sheet00813-0100-4811, Rev DACatalog 2008 - 2009Rosemount 3300 SeriesLevel-14SpecificationsGeneralProduct Rosemount 3300 Series Guided Wav

Página 7

Product Data Sheet00813-0100-4811, Rev DACatalog 2008 - 2009Level-15Rosemount 3300 SeriesMechanical, continuedMaterial Exposed to Tank Atmosphere • 31

Página 8

Product Data Sheet00813-0100-4811, Rev DACatalog 2008 - 2009Rosemount 3300 SeriesLevel-16POWER SUPPLY4-20 mA with HART® The input voltage (UI)for HART

Página 9

Product Data Sheet00813-0100-4811, Rev DACatalog 2008 - 2009Level-17Rosemount 3300 SeriesProduct CertificationsSAFETY NOTEA safety isolator such as a

Página 10 - Measuring Range

Product Data Sheet00813-0100-4811, Rev DACatalog 2008 - 2009Rosemount 3300 SeriesLevel-18National Supervision and Inspection Center for Explosion Prot

Página 11 - Interface

Product Data Sheet00813-0100-4811, Rev DACatalog 2008 - 2009Level-19Rosemount 3300 SeriesDimensional DrawingsCOAXIAL PROBE WITH FLANGE CONNECTION1.1 (

Página 12

Product Data Sheet00813-0100-4811, Rev DACatalog 2008 - 2009Rosemount 3300 SeriesLevel-2Measurement PrincipleRosemount 3300 Series is based on the Tim

Página 13 - Mechanical Considerations

Product Data Sheet00813-0100-4811, Rev DACatalog 2008 - 2009Rosemount 3300 SeriesLevel-20COAXIAL PROBE WITH THREADED CONNECTIONL ≤ 20 feet(6 m)1.1 (28

Página 14 - Specifications

Product Data Sheet00813-0100-4811, Rev DACatalog 2008 - 2009Level-21Rosemount 3300 SeriesRIGID TWIN LEAD PROBE4.1 (104)s601.0 (25)Ø 0.24 (6)Ø 0.31 (8)

Página 15

Product Data Sheet00813-0100-4811, Rev DACatalog 2008 - 2009Rosemount 3300 SeriesLevel-22FLEXIBLE TWIN LEAD PROBE1.4 (35)s603.5 (90) 3.5 (90)Ø 0.16 (4

Página 16

Product Data Sheet00813-0100-4811, Rev DACatalog 2008 - 2009Level-23Rosemount 3300 SeriesRIGID SINGLE LEAD PROBE WITH FLANGE CONNECTION4.3 (110)6.8 (1

Página 17 - Product Certifications

Product Data Sheet00813-0100-4811, Rev DACatalog 2008 - 2009Rosemount 3300 SeriesLevel-24RIGID SINGLE LEAD PROBE WITH THREADED CONNECTION4.1 (104)6.8

Página 18

Product Data Sheet00813-0100-4811, Rev DACatalog 2008 - 2009Level-25Rosemount 3300 SeriesFLEXIBLE SINGLE LEAD PROBE WITH FLANGE CONNECTION0.86 (22) /0

Página 19 - Dimensional Drawings

Product Data Sheet00813-0100-4811, Rev DACatalog 2008 - 2009Rosemount 3300 SeriesLevel-26FLEXIBLE SINGLE LEAD PROBE WITH THREADED CONNECTIONNPT 1 and

Página 20

Product Data Sheet00813-0100-4811, Rev DACatalog 2008 - 2009Level-27Rosemount 3300 SeriesSPECIAL FLANGES AND FLUSHING CONNECTION RINGSMasoneilan and F

Página 21

Product Data Sheet00813-0100-4811, Rev DACatalog 2008 - 2009Rosemount 3300 SeriesLevel-28Ordering InformationMODEL CODE 3301, LEVEL IN LIQUIDS Model P

Página 22

Product Data Sheet00813-0100-4811, Rev DACatalog 2008 - 2009Level-29Rosemount 3300 SeriesCode Probe Length UnitsE English (feet, in.)M Metric (meters,

Página 23

Product Data Sheet00813-0100-4811, Rev DACatalog 2008 - 2009Level-3Rosemount 3300 SeriesAPPLICATION EXAMPLES FOR GUIDED WAVE RADAR3301 3302Rosemount 3

Página 24

Product Data Sheet00813-0100-4811, Rev DACatalog 2008 - 2009Rosemount 3300 SeriesLevel-30Code Process Connection - Size / Type (consult factory for ot

Página 25

Product Data Sheet00813-0100-4811, Rev DACatalog 2008 - 2009Level-31Rosemount 3300 SeriesCode Hazardous Locations CertificationsNA No Hazardous Locati

Página 26

Product Data Sheet00813-0100-4811, Rev DACatalog 2008 - 2009Rosemount 3300 SeriesLevel-32MODEL CODE 3302, LEVEL AND INTERFACE IN LIQUIDSModel Product

Página 27

Product Data Sheet00813-0100-4811, Rev DACatalog 2008 - 2009Level-33Rosemount 3300 SeriesCode Probe Length UnitsE English (feet, in.)M Metric (meters,

Página 28 - Ordering Information

Product Data Sheet00813-0100-4811, Rev DACatalog 2008 - 2009Rosemount 3300 SeriesLevel-34Code Process Connection - Size / Type (consult factory for ot

Página 29

Product Data Sheet00813-0100-4811, Rev DACatalog 2008 - 2009Level-35Rosemount 3300 SeriesCode Hazardous Locations CertificationsNA No Hazardous Locati

Página 30

Product Data Sheet00813-0100-4811, Rev DACatalog 2008 - 2009Rosemount 3300 SeriesLevel-36ACCESSORIES MODEL 3301/3302• • Lower Range Value (LRV)• Upper

Página 31

Product Data Sheet00813-0100-4811, Rev DACatalog 2008 - 2009Level-37Rosemount 3300 Series

Página 32

© 2008 Rosemount Inc. All rights reserved.www.rosemount.comEmerson Process Management, Rosemount Inc.The AmericasEmerson Process Management8200 Market

Página 33

Product Data Sheet00813-0100-4811, Rev DACatalog 2008 - 2009Rosemount 3300 SeriesLevel-4System IntegrationINPUTS / OUTPUTSThe 3300 Series transmitter

Página 34

Product Data Sheet00813-0100-4811, Rev DACatalog 2008 - 2009Level-5Rosemount 3300 SeriesThe transmitter is available with Intrinsically Safe or Explos

Página 35

Product Data Sheet00813-0100-4811, Rev DACatalog 2008 - 2009Rosemount 3300 SeriesLevel-6Select Guided Wave Radar TransmitterA Rosemount 3300 Series tr

Página 36

Product Data Sheet00813-0100-4811, Rev DACatalog 2008 - 2009Level-7Rosemount 3300 SeriesThe following table gives the temperature ranges for standard

Página 37

Product Data Sheet00813-0100-4811, Rev DACatalog 2008 - 2009Rosemount 3300 SeriesLevel-8PROBESSeveral versions of the probes are available: Coaxial, R

Página 38

Product Data Sheet00813-0100-4811, Rev DACatalog 2008 - 2009Level-9Rosemount 3300 SeriesIn the table below: G=Good, NR=Not Recommended, AD=Application

Comentários a estes Manuais

Sem comentários