Product Data Sheet
00813-0100-4811, Rev DA
Catalog 2008 - 2009
Rosemount 3300 Series
Level-4
System Integration
INPUTS / OUTPUTS
The 3300 Series transmitter uses the same two wires
for both power supply and output signal
(loop-powered).
See page Level-16 for more information about power
supply.
Measurement data is transmitted as an analog
4-20 mA signal with a superimposed digital HART
®
signal. The HART
®
signal can be used in a multidrop
mode.
As an option, the 3300 Series is available with
Modbus output (requires separate power supply).
However, HART
®
communication is used for
configuration.
By sending the digital HART
®
signal to the optional
HART
®
Tri-loop, it is possible to have up to three
additional 4-20 mA analog signals.
See the Rosemount 333 HART
®
Tri-loop Product
Data Sheet (document number 00813-0100-4754)
for additional information.
3300 Series
transmitter
Display
Tri-loop
3 x 4-20 mA
Control
System
HART
®
Modem
PC
4-20 mA / HART
®
375 Field
Communicator
HART
®
Control
System
HART
®
Modem
PC
3300 Series
transmitter
Power
MODBUS
375 Field
Communicator
Max. cable length is
4000 ft (1200 m)