Product Data Sheet
00813-0100-4530, Rev AA
Catalog 2008 - 2009
Level-35
Rosemount 5300 Series
Code Hazardous Locations Certifications
KH FM, CSA, IECEx Intrinsic Safety
KI FISCO - ATEX, FM, CSA Intrinsic Safety
(10)
KJ FISCO - ATEX, FM, IECEX Intrinsic Safety
(10)
KK FISCO - ATEX, CSA, IECEX Intrinsic Safety
(10)
KL FISCO - FM, CSA, IECEX Intrinsic Safety
(10)
Code Options
M1 Integral digital display
P1 Hydrostatic testing
(11)
N2 NACE material recommendation per MR-0175
(12)
LS Long stud
(13)
9.8 in (250 mm) for flexible single lead probe to prevent contact with wall/nozzle.
Standard height is 3.9 in (100 mm) for probes 5A and 5B.
T1 Transient Protection Terminal Block (standard with FISCO options)
Sx and Px - Centering Discs Outer Diameter
S2 2 in. Centering disc SST
(14)
1.8 in. (45 mm)
S3 3 in. Centering disc SST
(14)
2.7 in. (68 mm)
S4 4 in. Centering disc SST
(14)
3.6 in. (92 mm)
S6 6 in. Centering disc SST
(14)
5.55 in. (141 mm)
S8 8 in. Centering disc SST
(14)
7.40 in. (188 mm)
P2 2 in. Centering disc PTFE
(15)
1.8 in. (45 mm)
P3 3 in. Centering disc PTFE
(15)
2.7 in. (68 mm)
P4 4 in. Centering disc PTFE
(15)
3.6 in. (92 mm)
P6 6 in. Centering disc PTFE
(15)
5.55 in. (141 mm)
P8 8 in. Centering disc PTFE
(15)
7.40 in. (188 mm)
Cx - Special Configuration (Software)
C1 Factory configuration (CDS required with order)
C4 Namur alarm and saturation levels, high alarm
C5 Namur alarm and saturation levels, low alarm
C8 Low alarm
(16)
(standard Rosemount alarm and saturation levels)
Qx - Special Certifications
Q4 Calibration Data Certification
Q8 Material Traceability Certification per EN 10204 3.1
(17)
(1) Not available with Flame/Explosionproof approvals (E1, E5, E6, E7, KA, KB, KC, and KD)
(2) Process seal rating. Final rating depends on flange and O-ring selection. See “Tank Connection” on page 7.
(3) Requires option None for sealing (no O-ring). Only for SST (“Material of Construction”, code 1).
(4) For other materials, consult factory.
(5) Requires High Temperature High Pressure (code H) or High Pressure (code P) probe.
(6) Requires model 5301.
(7) Only available with standard temperature and pressure (code S).
(8) Extra length for fastening is added in factory.
(9) Probe weight included if applicable. Give the total probe length in feet and inches or meters and centimeters, depending on selected probe length unit.
If tank height is unknown, please round up to an even length when ordering. Probes can be cut to exact length in field. Maximum allowable length is
determined by process conditions. See “Mechanical Considerations” on page 15 for more probe length guidance.
(10) Requires Foundation™ fieldbus signal output (U
i
parameter listed in “Product Certifications” on page 21).
(11) For standard tank connection, only available with flange.
(12) Valid for probe type 3A, 3B and 4A.
(13) Not available with PTFE covered probes.
(14) Available for SST probes, type 2A, 4A and 5A. For more information, see “Centering Discs” on page 13.
(15) Available for SST probes, type 2A, 4A and 5A, except for HTHP.
(16) The standard alarm setting is high.
(17) Certificate includes all pressure retaining wetted parts.
Example Model String: 5301-H-A-1-S-1-V-1A-M-002-05-AA-I1-M1C1. E-002-05, means 2 ft and 5 in. probe length. M-002-05, means 2.05 m.
Vista de página 34