EZH and EZHSO Series
12
Table 4. Torque Specications
PART NAME
TORQUE SPECIFICATIONS
Body Size
NPS 1 / DN 25 NPS 2 / DN 50 NPS 3 / DN 80 NPS 4 / DN 100
ft-lbs N•m ft-lbs N•m ft-lbs N•m ft-lbs N•m
Indicator Fitting or Plug (key 141) 10 to 30 14 to 41 10 to 30 14 to 41 10 to 30 14 to 41 10 to 30 14 to 41
Stud Nuts (key 26) 45 to 50 61 to 68 45 to 50 61 to 68 80 to 95 108 to 129 - - - -
Socket Head Cap Screws (key 16) 50 to 70
(1)
5.6 to 7.9
(1)
50 to 70
(1)
6 to 7.9
(1)
50 to 70
(1)
6.2 to 7.9
(1)
100 to 115
(1)
11 to 13
(1)
Stud Bolts (key 24) 50 to 70 68 to 95 50 to 70 68 to 75 100 to 120 136 to 163 - - - -
Cap Screws (key 21) 50 to 55 68 to 75 130 to 150 176 to 203 250 to 270 339 to 366 280 to 310 380 to 420
Cap Screws (key 6) 50 to 60 68 to 81 50 to 60 68 to 81 70 to 95 95 to 129 140 to 155 190 to 210
Socket Head Cap Screws (key 33) 30 to 40
(1)
3.4 to 4.5
(1)
50 to 60
(1)
5.6 to 6.8
(1)
80 to 100
(1)
9 to 11
(1)
80 to 100
(1)
9 to 11
(1)
Smart Screws (key 68) - - - - - - - - - - - - 31 to 40
(1)
3.5 to 4.5
(1)
Socket Head Cap Screws (key 74) - - - - - - - - - - - - 26 to 35
(1)
2.9 to 4
(1)
Cap Screws (key 77) - - - - - - - - - - - - 90 to 110 122 to 149
Sleeve Guide (key 61) - - - - - - - - - - - - 130 to 140 176 to 190
Cap Screw (key 154) 16
(1)
1.8
(1)
50
(1)
5.6
(1)
10 14 2.9 to 3.5 3.9 to 4.7
Stem Nut (key 151) 32 43 32 43 45 61 45 to 50 61 to 68
Stem Nut (key 155) 30 41 - - - - - - - - - - - -
Hex Nut (key 152) - - - - 40
54 60 81 45 to 50 61 to 68
1. Torque specications are given in in-lbs.
4. Vent pressure from bleed line until regulator closes
and then shut-off vent. A full bore NPS 1/4 ball
valve for the vent line is preferred.
5. Slowly open downstream valve, making sure
that there is a constant sufcient pressure drop
across the regulator. If downstream pressure
climbs too close to upstream pressure (a minimum
DP of 55 psi / 3.8 bar must be guaranteed), the
regulator will again fully open. In this case, start-up
procedure needs to be repeated.
For a single regulator (Figure 4), set the pilot to
the desired outlet (control) pressure according to the
Pilot Adjustment procedure.
For a wide-open downstream monitor installation
(Figure 5), adjust the upstream working pilot until
intermediate pressure is higher than the desired
setpoint of the monitor pilot. Adjust the downstream
monitoring pilot to the desired monitoring takeover
pressure. Reduce the upstream pilot to the normal
outlet pressure setting.
For a wide-open upstream monitor installation
(Figure 5), adjust the downstream working pilot to a
setpoint higher than the setpoint of the monitor pilot.
Adjust the upstream monitoring pilot to the desired
monitoring takeover pressure. Reduce the downstream
pilot to the normal outlet pressure setting.
For a working monitor installation (Figure 6),
adjust the setpoint of the upstream monitor pilot
Type PRX/125 to the desired maximum pressure.
Adjust the upstream working pilot Type PRX/120 to
the desired intermediate pressure setting. Adjust the
downstream pilot to a pressure setting slightly above
the upstream monitor pilot pressure setting. Adjust the
upstream monitor pilot to its desired setpoint. Establish
nal desired downstream pressure by adjusting the
downstream working regulator pilot.
6. After adjusting the PRX Series pilot(s) to the
desired pressure setting(s), slowly open the
downstream block valve wide open.
7. Close the bypass valve, if used.
Shutdown
CAUTION
If the pilot bleed control line pressure is
shutdown rst, the downstream system
may be subjected to full inlet pressure.