Emerson FM-3 Guia de Resolução de Problemas Página 46

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 45
42
Appendix D: Ohming Motor Procedure
Ohming
Out Motor
Disconnect
Motor Cable
from Motor
Connect Ohmmeter
Leads between
Pins A and B
on Motor Connector
Connect Ohmmeter
Leads between
Pins B and C
on Motor Connector
phase to phase test
Connect Ohmmeter
Leads between
Pins D and C
on Motor Connector
phase to ground test
Ohmmeter Shall
Read Inifinity
(open circuit)
Connect Ohmmeter
Leads between
Pins D and B
on Motor Connector
phase to ground test
Ohmmeter Shall
Read Inifinity
(open circuit)
Connect Ohmmeter
Leads between
Pins D and A
on Motor Connector
phase to ground test
Ohmmeter Shall
Read Inifinity
(open circuit)
Any Reading in the entire test
that does not fall within specified limits phase to phase
or meet the exact reading phase to ground
is to be considered failing the test
Slowly Rotate
Motor Shaft
CW or CCW
Observe Ohmmeter Reading
See Resistance chart this page
for motor under test
Slowly Rotate
Motor Shaft
CW or CCW
Observe Ohmmeter Reading
See Resistance chart this page
for motor under test
Slowly Rotate
Motor Shaft
CW or CCW
Observe Ohmmeter Reading
See Resistance chart this page
for motor under test
Connect Ohmmeter
Leads between
Pins A and C
on Motor Connector
phase to phase test
Vista de página 45
1 2 ... 41 42 43 44 45 46 47 48 49 50 51 ... 59 60

Comentários a estes Manuais

Sem comentários