Vista de página 27
28 Micro Motion
®
ELITE
®
Flow and Density Meters
Hazardous area classifications continued
Models CMFS010 and CMFS015 with Model 2200S transmitter
Use the above graph to determine the temperature class for a given fluid and ambient temperature. The maximum surface
temperature for dust is as follows: T4:T 130°C, T3:T 195°C, T2 to T1:T 207°C.
Ambient temperature range Ta –40 °C to +60 °C
Models CMF400 with Model 2200S transmitter
Use the above graph to determine the temperature class for a given fluid and ambient temperature. The maximum surface
temperature for dust is as follows: T4:T 130°C, T3:T 195°C, T2 to T1:T 234°C
Ambient temperature range Ta –40 °C to +60 °C
Sensor fluid temp (°C)
Max ambient temp (°C)
Sensor fluid temp (°C)
Max ambient temp (°C)