Installation arrangements vary, but in any installation
it is important to open and close valves slowly. When
shutting down the system, close the upstream supply
shutoff valve rst. Refer to Figure 3.
Valve parts are subject to normal wear and must
be inspected and replaced as necessary. The
frequency of inspection and replacement of parts
depends on the severity of service conditions and the
requirements of local, state, and federal regulations.
Due to the care Regulator Technologies. takes in
meeting all manufacturing requirements, use only
replacement parts manufactured or furnished by
Regulator Technologies.
All O-Rings, gaskets, and seals should be lubricated
with a good grade of general purpose lubricant and
installed gently rather than forced into position.
Approved lubricant, sealants, and adhesive are
as follows:
: Dow Corning
®
111
: Loctite
®
PST #592, Teon
®
Tape
: Loctite
®
#222
Figure 4. Spring Case, Adjusting Screw, and Actuator Cap
W8160
Be certain that nameplates are updated to accurately
indicate any eld changes in equipment, materials,
service conditions, or pressure settings.
1. Visually inspect the unit to ensure tight connections,
tight seals, and safe operation.
2. Observe the blanketing pressure.
3. Inspect the inlet pressure for the proper pressure
(stamped on the valve nameplate).
1. Visually inspect the unit to ensure tight connections,
tight seals, and safe operation.
2. Observe the blanketing pressure.
3. Inspect the inlet pressure for the proper pressure
(stamped on the valve nameplate).
4. Visually inspect valve for any external damage.
5. If there is evidence of leakage or unstable
internal motion, a rebuild with seal replacement
and re-lubrication may be in order.