ACCURACY
SETPOINT + / - 1% ABS SET RANGE
PART NUMBER /
COLOR
2 psig -0.17 psi 0.17 psi 1 to 2 psig
GE30199X012 /
Yellow Stripe
0.14 bar -12 mbar 12 mbar 0.07 to 0.14 bar
Table 18. CP200 Series Internal Registration Flow Capacities for 2 psig / 0.14 bar Setpoint
with 1% ABS Pressure Factor Accuracy (PFM Approved)
CAPACITIES IN SCFH / Nm
3
/h OF 0.6 SPECIFIC GRAVITY NATURAL GAS
Inlet Pressure
Orice Size, Inch / mm
3/16 / 4.8 1/4 / 6.4 3/8 / 9.5 1/2 / 13
SCFH Nm
3
/h SCFH Nm
3
/h SCFH Nm
3
/h SCFH Nm
3
/h
psig bar Body Size: 3/4 NPT
10 0.69 580 15.5 1100 29.5 2000 53.6 2900 77.7
15 1.0 770 20.6 1500 40.2 2500 67.0 3200 85.8
20 1.4 970 26.0 1800 48.2 2800 75.0 3200 85.8
25 1.7 1100 29.5 2100 56.3 3000 80.4 3200 85.8
30 2.1 1300 34.8 2300 61.6 3100 83.1 3200 85.8
40 2.8 1600 42.9 2900 77.7 3100 83.1
50 3.4 1800 48.2 3300 88.4 3100 83.1
60 4.1 1800 48.2 3400 91.1 2600 69.7
80 5.5 1800 48.2 3500 93.8
100 6.9 1800 48.2
125 8.6
psig bar Body Size: 1 NPT
10 0.69 580 15.5 1200 32.2 1800 48.2 2500 67.0
15 1.0 770 20.6 1500 40.2 2800 75.0 3200 85.8
20 1.4 1000 26.8 1900 50.9 2900 77.7 3200 85.8
25 1.7 1200 32.2 2200 59.0 3200 85.8 3200 85.8
30 2.1 1300 34.8 2500 67.0 3200 85.8 3200 85.8
40 2.8 1600 42.9 3100 83.1 4200 113
50 3.4 1800 48.2 3700 99.2 4200 113
60 4.1 1800 48.2 3900 105 4200 113
80 5.5 1800 48.2 3900 105
100 6.9 3900 105
125 8.6
psig bar Body Size: 1-1/4 NPT
10 0.69 580 15.5 1100 29.5 2400 64.3 2900 77.7
15 1.0 770 20.6 1600 42.9 3200 85.8 3200 85.8
20 1.4 1000 26.8 1900 50.9 3200 85.8 3200 85.8
25 1.7 1200 32.2 2200 59.0 3200 85.8 3200 85.8
30 2.1 1300 34.8 2400 64.3 3200 85.8 3200 85.8
40 2.8 1600 42.9 3000 80.4 4200 113
50 3.4 1800 48.2 3700 99.2 4200 113
60 4.1 1800 48.2 4200 113 4200 113
80 5.5 1800 48.2
100 6.9
125 8.6
Shaded areas indicate values that are limited due to boost effects.
Blank areas indicate where maximum operating inlet pressure for a given orice size is exceeded.