CSB400 Series
2
Specications
The Specications section lists the specications for the CSB400 Series Regulators. The following information is stamped
on the nameplate of CSB400 Series: Type and Class, Maximum Outlet Pressure and Spring Range.
Pressure Registration
Internal, External or Dual (Internal and External)
Operating Temperature (TS)
(1)(2)
According to PED Standards:
All Types: -20 to 66°C / -4 to 150°F
Non-PED with standard construction:
Types CSB400/CSB404, CSB420/CSB424:
-20 to 66°C / -4 to 150°F
Types CSB450/CSB454
(3)
:
-30 to 66°C / -20 to 150°F
Non-PED with low temperature construction:
Types CSB400F/CSB404F
(3)
, CSB420F/CB424F
(3)
:
-30 to 66°C / -20 to 150°F
Approximate Weights
With Threaded body
Type CSB400: 4.1 kg / 9 pounds
Type CSB403: 9.1 kg / 20 pounds
Type CSB404: 5.0 kg / 11 pounds
With Flanged Body:
Add 4.1 kg / 9 pounds to threaded weights
listed above
PED Conformity Statement and Information
The CSB400 Product Series is in conformity with the
Pressure Equipment Directive PED 97/23/EC. The
exceptions to this previous statement are the
Types CSB403 and CSB423. Both of these types are
not yet certied to conform with the PED Directive.
Pressure regulator does not require any
supplementary upstream safety accessory for
protection against overpressure compared with
its design pressure PS, when upstream reducing
station is sized for a max downstream incidental
MIP
d
<= 1.1 P
S
.
PED Related Information
See Table 2
Available Congurations
See Table 1
Regulator Type: Differential Strength (DS)
Accuracy Class: Up to AC5
(depending on Outlet Pressure)
Lock-up Class: Up to SG10
(depending on Outlet Pressure)
Failure Mode: Fail Open (FO)
Body Sizes and End Connection Styles
See Table 5
Integral Strength (IS) Pressure Ratings
(1)
See Table 3
Differential Strength (DS) Pressure Ratings and
Flow and Sizing Coefcients
(1)
See Table 4
Operating Pressure Ranges
(1)
Regulator: See Table 6
Integral True-Monitor™ Module: See Table 7
Slam-Shut Module: See Table 8
Maximum Outlet Pressures
(1)
Emergency: 4.0 bar / 58 psig
To Avoid Internal Parts Damage:
Type CSB450: 1 bar / 14.5 psig above outlet
pressure setting
All other Types: 0.34 bar / 5 psig above outlet
pressure setting
Operating: 3.0 bar / 43.5 psig
Spring Case Vent Connection
1 NPT
Orice Size
17.5 mm / 11/16 inch
1. The pressure/temperature limits in this Instruction Manual or any applicable standard limitation should not be exceeded.
2. Standard token relief set values listed in Table 8 are based on -20 to 60°C / -4 to 140°F.
3. Product has passed Emerson Process Management Regulator Technologies, Inc. (Regulator Technologies) testing for lockup, relief start-to-discharge and reseal down to -40°.
Vista de página 1