27
Reference Manual
00809-0100-4803, Rev DA
Appendix A: Reference Data
April 2013
Specifications and Reference Data
A.3 Ordering information
A.3.1 Rosemount 3051S MultiVariable transmitter
Table 1. Rosemount 3051S Scalable MultiVariable transmitter ordering information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.
Model Transmitter Type
3051SMV Scalable MultiVariable Transmitter
Performance Class
Standard Standard
3051SMV MultiVariable SuperModule, Measurement Types 1 and 2
3
(1)
Ultra for Flow: 0.04% reading DP accuracy, 200:1 rangedown,10-year stability, 12-year limited warranty ★
5 Classic MV: 0.04% span DP accuracy, 100:1 rangedown, 5-year stability ★
3051SMV Single Variable SuperModule, Measurement Types 3 and 4
1
(2)
Ultra: 0.025% span DP accuracy, 200:1 rangedown, 10-year stability, 12-year limited warranty ★
2 Classic: 0.055% span DP accuracy, 100:1 rangedown, 5-year stability ★
3
(1)
Ultra for Flow: 0.04% reading DP accuracy, 200:1 rangedown,10-year stability, 12-year limited warranty ★
MultiVariable Type
Standard Standard
M MultiVariable Measurement with Fully Compensated Mass and Energy Flow ★
P MultiVariable Measurement with Direct Process Variable Output ★
Measurement Type
Standard Standard
1 Differential Pressure, Static Pressure, and Temperature ★
2 Differential Pressure and Static Pressure ★
3 Differential Pressure and Temperature ★
4 Differential Pressure ★
Differential Pressure Range
Standard Standard
0
(2)(3)
-3 to 3 inH
2
O (-7,47 to 7,47 mbar) ★
1 -25 to 25 inH
2
O (-62,2 to 62,2 mbar) ★
2 -250 to 250 inH
2
O (-623 to 623 mbar) ★
3 -1000 to 1000 inH
2
O (-2,5 to 2,5 bar) ★
4 -300 to 300 psi (-20,7 to 20,7 bar) ★
5 -2000 to 2000 psi (-137,9 to 137,9 bar) ★
Static Pressure Type
Standard Standard
N
(4)
None ★
A Absolute ★
G Gage ★
Static Pressure Range Absolute Gage
Standard Standard
N
(4)
None ★
3 Range 3 0.5 to 800 psia (0,03 to 55,2 bar) -14.2 to 800 psig (-0,98 to 55,2 bar) ★
4
(5)
Range 4 0.5 to 3626 psia (0,03 to 250 bar) -14.2 to 3626 psig (-0,98 to 250 bar) ★