Type LR128
D103578X012
Instruction Manual
November 2014
www.fisherregulators.com
Type LR128 Relief Valve or
Backpressure Liquid Regulator
Figure 1. Type LR128 Relief Valve or Backpressure Regulator and Type MR98H Pilot
!
WARNING
Failure to follow these instructions or
to properly install and maintain this
equipment could result in bursting
of the equipment and/or chemical
contamination causing property damage
and personal injury or death.
Fisher
®
relief valves and backpressure
regulators must be installed, operated
and maintained in accordance with
federal, state and local codes, rules
and regulations and Emerson Process
Management Regulator Technologies, Inc.
(Emerson™) instructions.
If the relief valve or backpressure regulator
discharges process uid or a if leak
develops in the system, service to the unit
may be required. Failure to correct trouble
could result in a hazardous condition.
Call a quali ed service person to service
the unit. Installation, operation and
maintenance procedures performed
by unquali ed personnel may result
in improper adjustment and unsafe
operation. Either condition may result
in equipment damage or personal
injury. Only a quali ed person must
install or service the relief valve or
backpressure regulator.
The Type LR128 is designed for liquid
service. Do not operate the regulator
in applications where temperatures are
below the process  uid’s freezing point
or above its boiling point which are
dependent on the process  uid and the
application pressures.
TYPE LR128 REGULATOR
Backpressure Liquid Regulator
TYPE MR98H PILOT
Vista de página 0
1 2 3 4 5 6 ... 27 28

Resumo do Conteúdo

Página 1 - Backpressure Liquid Regulator

Type LR128D103578X012Instruction ManualNovember 2014www.fisherregulators.comType LR128 Relief Valve or Backpressure Liquid RegulatorFigure 1. Type LR1

Página 2

Type LR12810Table 6. Type LR128 Main Valve Minimum Differential Pressures(1)MAIN VALVE BODY SIZEDIAPHRAGMMINIMUM DIFFERENTIAL, PERCENT OF CAPACITYFor

Página 3

Type LR12811Table 8. Troubleshooting GuideISSUE POSSIBLE SOLUTION (SEE FIGURES 7 AND 14 FOR PARTS LOCATION) Unit does not provide tight shutoff when

Página 4

Type LR12812B2615INDICATOR PROTECTOR (KEY 22)HEX NUTS(KEY 4)BONNET(KEY 2)O-RING(KEY 28)MAIN SPRING(KEY 12)CAP SCREWS (KEY 3)INDICATOR COVER (KEY 21)IN

Página 5

Type LR1281349B6019_AMAIN VALVE ASSEMBLY FOR 1 IN. / DN 25 BODY SIZE Figure 7. Type LR128 Main ValveAPPLY LUBRICANT(1):L1 = LITHIUM POLYMER TYPE LUBRI

Página 6

Type LR1281448B2142_CMAIN VALVE ASSEMBLY FOR 2, 3 AND 4 IN. / DN 50, 80 AND 100 BODY SIZES Figure 7. Type LR128 Main Valve (continued)APPLY LUBRICANT

Página 7

Type LR12815Figure 8. Type LR128 Nameplate and Flow ArrowFigure 10. Type LR128 Cage O-ring PlacementFigure 11. Type LR128 Travel Indicator Plug Option

Página 8

Type LR12816Diaphragm and Plug Assembly MaintenanceThe diaphragm and plug assembly can be replaced as a single unit (a diaphragm cartridge) or individ

Página 9

Type LR12817!WARNINGAvoid personal injury or damage to property from sudden release of pressure or uncontrolled process uid. Before starting to disas

Página 10 - Type LR128

Type LR12818Type MR98H Pilot Maintenance!WARNINGTo avoid personal injury, property damage or equipment damage caused by sudden release of pressure or

Página 11

Type LR12819Figure 14. Type MR98H Pilot AssemblyL2 1517113129L2 10L2(2)161228586329L2735814L2L2L2L1GF04916APPLY LUBRICANT / SEALANT(1):L1 = GENERAL PU

Página 12

Type LR1282IntroductionScope of the ManualThis Instruction Manual provides installation, startup, adjustment, maintenance and parts ordering informati

Página 13

Type LR12820Figure 16. Type 112 Restrictor20B4393-EAPPLY LUBRICANT / SEALANT(1):S = THREAD SEALANTL = ANTI-SEIZE LUBRICANT1. Lubricant and sealant mus

Página 14

Type LR12821CRITERIA17E68 NITRILE (NBR) (STANDARD)17E97 NITRILE (NBR) 17E88 FLUOROCARBON (FKM)Liquid Temperature -20 to 150°F / -29 to 66°C 0 to 150°F

Página 15

Type LR12822Figure 18. Standard Type LR128 with Type MR98H Pilot and Type 112 Restrictor4529TYPE MR98H PILOTTYPE 112RESTRICTORERAA031094529

Página 16

Type LR12823ERAA03110Figure 19. Type LR128 with Type MR98H Pilot and Type 112 Restrictor with Pre-piped Pilot SupplyTYPE 112RESTRICTOR456162602959TYPE

Página 17

Type LR12824Key Description Part NumberParts ListMain Valve (Figures 6 to 13)Key Description Part Number Parts Kits Diaphragm Car

Página 18

Type LR12825BODY SIZEBODY MATERIAL END CONNECTION STYLE PART NUMBERIn. DN1 25WCC SteelNPT GE11581X012SWE GE11440X012CL150 RF GE11583X012CL300 RF GE

Página 19

Type LR1282611 Bottom Plug, Stainless steel 1 in. / DN 25 body 19B2407X012 2 in. / DN 50 body 18B2127X012 3 in. / DN 80 body 18B8513X012

Página 20

Type LR12827* Recommended spare part.Type MR98H Pilot (Figure 14)Key Description Part Number Parts Kit (includes keys: 3, 4, 12, 29, 59 and 63)

Página 21

Type LR128©Emerson Process Management Regulator Technologies, Inc., 2012, 2014; All Rights ReservedThe Emerson logo is a trademark and service mark of

Página 22

Type LR1283Figure 2. Type LR128 Operational SchematicINLET PRESSUREOUTLET PRESSUREATMOSPHERIC PRESSURELOADING PRESSURETYPE LR128 WITH TYPE MR98H PILOT

Página 23

Type LR1284Pilot Type DescriptionType MR98H – High-pressure relief pilot for 25 to 375 psig / 1.7 to 25.9 bar set pressures. Designed to handle inlet

Página 24

Type LR1285Table 1. Type LR128 Main Valve Body Sizes, End Connection Styles, Structural Design Ratings and Maximum Operating Inlet Pressures(1)MAIN VA

Página 25

Type LR1286NoteThe Type LR128 internal inlet strainer is intended to prevent occasional large particles from entering the main valve. If the owing me

Página 26

Type LR1287RELIEF PRESSURE CONTROLBACKPRESSURE CONTROLFigure 3. Typical Type LR128 Installation SchematicA - VENT (TO DOWNSTREAM PIPING)C - TO TYPE LR

Página 27

Type LR1288PILOT SUPPLY CONNECTION: 1/4 NPT PIPE CONNECTS TO UPSTREAM PILOT SUPPLY TAPLOADING CONNECTION: 1/4 NPT PIPE CONNECTS TO TYPE LR128 DIAPHRAG

Página 28

Type LR1289W4559_1RESTRICTOR ADJUSTMENTFigure 5. Restrictor Adjustment and Restrictor Setting GuideRESTRICTOR SETTING GUIDETYPE 112 RESTRICTOR ADJUSTM