Reference Manual
00809-0600-4026, Rev BA
December 2011
Rosemount Process Radar
2-4
Refer to Rosemount 5300 Series Reference Manual (Document No.
00809-0100-4530) for details regarding the mounting of transmitter
head/probe.
Bracket Mounting, on Wall
1. Mount the bracket directly to the wall
with screws suitable for the purpose.
2. Mount the transmitter with probe to the
bracket and secure the installation with
the three supplied screws.
Bracket Mounting, on Pipe
1. Put the two U-bolts through the holes
of the bracket. Holes are available for
both vertical and horizontal pipe
mounting.
2. Put the clamping brackets on the
U-bolts and around the pipe.
3. Fasten the bracket to the pipe using
the four supplied nuts.
4. Mount the transmitter with probe to the
bracket and secure with the three
supplied screws.
See the Rosemount 5300 Series
Reference Manual (Document No.
00809-0100-4530) for more installation
details.
U-bolts
Clamping
brackets
Bracket
Transmitter
housing
Bracket
Probe
Horizontal mounting
Probe
Transmitter
housing
Vertical mounting
Probe
Transmitter
housing