Emerson ROSEMOUNT 5300 Especificações Página 41

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 106
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 40
Reference Manual
00809-0600-4026, Rev BA
December 2011
3-9
Rosemount Process Radar
Figure 3-9. Loop test for Analog
Out 1
Echo Curve Verification
1. Download and review the echo-curve
Figure 3-10. The Echo Curve
presents all visible echoes
2. Verify that the reference pulse is detected
3. Review peak amplitudes
Verify that the probe end pulse is visible. If the probe is grounded or SST
centering disk is used, the pulse is positive. Otherwise the pulse will be
negative.
Verify that no disturbing echoes are present above the Surface
Threshold (ATC).
3.0 4.0
5.0
6.0
Interface Threshold
Surface Threshold
(ATC)
Probe End Threshold
Reference Threshold
Full Tank Threshold
Amplitude, mV
Distance, m
Reference
Probe End
Vista de página 40