108 Transmitter Configuration and Use: Series 1000 and 2000 Transmitters
Pressure Compensation, Temperature Compensation, and Polling continued
With ProLink II
To configure polling with ProLink II:
1. Verify that pressure compensation or external temperature compensation has been enabled (see
Section 9.2 and Section 9.3).
2. If you are polling for temperature, open the
Configuration panel from the ProLink menu,
click the
Temperature tab, and ensure that the External Temperature value has not been set.
The default value is 32.00 °F (0 °C). Click Apply if necessary.
3. Click the
Polled Variables tab.
4. For Polled Variable 1:
a. Click the arrow in the
Polling Control box, and select a HART polling method from the
list. Choose
Primary if the external device will probably be accessed by another device
acting as a secondary master (e.g., a Communicator). Choose
Secondary if the external
device will probably be accessed by another device acting as a primary master.
Note: If you are configuring both Polled Variable 1 and Polled Variable 2, use the same Polling
Control setting for both. If you do not, Poll as Primary will be used for both devices.
b. Click
Apply. The additional polling parameters are now available for configuration.
c. In the
External Tag box, enter the HART tag of the external device that you will poll.
d. Click the arrow in the
Variable Type box, and select a process variable.
e. Click
Apply.
5. Repeat these steps for Polled Variable 2, if required.
With a Communicator
To configure polling with a Communicator:
1. Verify that pressure compensation or external temperature compensation has been enabled (see
Section 9.2 and Section 9.3).
2. Press
4, 1.
3. Select
Polling Setup.
4. Select
Poll Control 1.
a. Select a HART polling method from the list. Choose
Primary if the external device will
probably be accessed by another device acting as a secondary master (e.g., a
Communicator). Choose
Secondary if the external device will probably be accessed by
another device acting as a primary master.
b. Press ENTER.
Note: If you are configuring both Polled Variable 1 and Polled Variable 2, use the same Polling
Control setting for both. If you do not, Poll as Primary will be used for both devices.
5. Select
Ext Dev Tag 1.
a. Enter the HART tag of the external device to be polled.
b. Press ENTER.