130 Transmitter Configuration and Use: Series 1000 and 2000 Transmitters
Troubleshooting continued
10.24 Checking the test points
Some status alarms that indicate a sensor failure or overrange condition can be caused by problems
other than a failed sensor. You can diagnose sensor failure or overrange status alarms by checking the
flowmeter test points. The test points include left and right pickoff voltages, drive gain, and tube
frequency. These values describe the current operation of the sensor.
10.24.1 Obtaining the test points
You can obtain the test points with a Communicator or ProLink II software.
With a Communicator
To obtain the test points with a Communicator:
1. Select
Diag/Service.
2. Select
Test Points.
3. Select
Drive.
a. Write down the drive gain.
b. Press
EXIT.
4. Select
LPO.
a. Write down the left pickoff voltage.
b. Press
EXIT.
5. Select
RPO.
a. Write down the right pickoff voltage.
b. Press
EXIT.
6. Select
Tube.
a. Write down the tube frequency.
b. Press
EXIT.
With ProLink II software
To obtain the test points with ProLink II software:
1. Select
Diagnostic Information from the ProLink menu.
2. Write down the values you find in the
Tube Frequency box, the Left Pickoff box, the Right
Pickoff
box, and the Drive Gain box.
10.24.2 Evaluating the test points
Use the following guidelines to evaluate the test points:
If the drive gain is unstable, refer to Section 10.24.3.
If the value for the left or right pickoff does not equal the appropriate value from Table 10-8,
based on the sensor flow tube frequency, refer to Section 10.24.5.
If the values for the left and right pickoffs equal the appropriate values from Table 10-8, based
on the sensor flow tube frequency, record your troubleshooting data and contact the Micro
Motion Customer Service Department for assistance. See Section 10.3.