48 Transmitter Configuration and Use: Series 1000 and 2000 Transmitters
Required Transmitter Configuration continued
.
To configure the channels, see the menu flowcharts in Figure 6-4.
Figure 6-4 Configuring the channels
Table 6-2 Channel configuration options
Terminals
Default Process
Variable AssignmentChannel 2500 2700 Configuration Option Power
A 21 & 22 1 & 2 mA output 1
(with Bell 202 HART)
Mass flow Internal
B 23 & 24 3 & 4 mA output 2 (default)
(1)
(1) If set to MAO2, internal power is required.
Density Internal or external
(2)
(2) If set to external power, you must provide power to the outputs.
Frequency output (FO) Mass flow
Discrete output 1 (DO1)
(3)
(3) Because DO1 uses the same circuitry as the frequency output, it is not possible to configure both FO and DO1. If both a frequency
output and a discrete output are required, configure Channel B as the FO and Channel C as DO2.
Fwd/Rev
C 31 & 32 5 & 6 FO (default)
(3)(4)
(4) When configured for two FOs (dual pulse), FO2 is generated from the same FO signal sent to the first FO. FO2 is electrically isolated
but not independent.
Mass flow Internal or external
(2)
Discrete output 2 (DO2) Flow switch
Discrete input (DI) None
Communicator
ProLink II
Channel Configuration
Configuration
On-Line Menu
Detailed Setup
Config outputs
Channel setup
On-Line MenuProLink Menu
Vista de página 57